How an Inverter Functions, How to Repair Inverters - General Tips

In this post we will try to learn how to diagnose and repair an inverter, by comprehensively learning the various stages of an inverter, and how a basic inverter functions.

Before we discuss how to repair an inverter it would be important for you to first get fully informed regarding how does an inverter worka. The following content walks you through both the aspects which can prove very useful to any electronic technician.

 Stages of an Inverter


As the name suggests DC to AC inverter is an electronic device which is able to convert a DC potential normally derived from a lead-acid battery into a stepped-up AC potential which may be quite comparable to the voltage that is found in our domestic AC Mains outlets.

Repairing sophisticated inverters are not easy due to their many involved complex stages and requires expertise in the field. Inverters which provide sine wave outputs or the ones which use PWM technology to generate modified sine wave can be difficult to diagnose and troubleshoot for the folks who are relatively new to electronics.

However, simpler inverter designs that involve basic operating principles can be repaired even by a person who is not specifically an expert with electronics.

Before we move into the fault finding details it would be important to discuss how does an inverter work and the different stages normally an inverter may comprise:

An inverter in its most basic form may be divided into three fundamental stages viz. oscillator, driver and the transformer output stage.

Oscillator:


This stage is basically responsible for the generation of oscillating pulses either through an IC circuit or a transistorized circuit.

These oscillations are basically the productions of alternate battery positive and negative (ground) voltage peaks with a particular specified frequency (number of positive peaks per second.) Such oscillations are generally in the form of square pillars and are termed as square waves, and the inverters operating with such oscillators are called square wave inverters.

The above generated square wave pulses though are too weak and can never be utilized to drive high current output transformers. Therefore these pulses are fed to the next amplifier stage for the required task.

For info on Inverter oscillators you can also refer to the complete tutorial which explains how to design an Inverter from the scratch

Booster or Amplifier (Driver):


Here the received oscillating frequency is suitably amplified to high current levels using either power transistors or Mosfets.

Though the boosted response is an AC, but is still at the battery supply voltage level and therefore cannot be used to operate electrical appliances which work at higher voltage AC potentials.

The amplified voltage is therefore finally applied to the output transformer secondary winding.

Output Power Transformer:


We all know how a transformer works; in AC/DC power supplies it is normally used to step-down the applied input mains AC to the lower specified AC levels through magnetic induction of its two windings.

In inverters a transformer is used for similar purpose but with just opposite orientation, i.e. here the low level AC from the above discussed electronic stages is applied to the secondary windings resulting in an induced stepped up voltage across the primary winding of the transformer.

This voltage is finally utilized for powering the various household electrical gadgets like lights, fans, mixers, soldering irons etc.

"You may also want to learn how to design an Inverter Transformer"

Inverter Block Diagram (Push Pull)


push pull inverter block diagram

Basic Principle of Operation of an Inverter

The above diagram shows the most fundamental design of an inverter, the working principle becomes the back bone for all conventional inverter designs, from the simplest to the most sophisticated ones.

The functioning of the shown design may be understood from the following points:

1) The positive from the battery powers the oscillator IC (Vcc pin), and also the center tap of the transformer.

2) The oscillator IC when powered starts producing alternately switching Hi/lo pulses across its output pins PinA and PinB, at some given frequency rate, mostly at 50Hz, or 60Hz depending as per the country specs.

3) These pinouts can be seen connected with the relevant power devices #1, and #2, which could be mosfets or power BJTs.

3) At any instant when PinA is high, and PinB is low, the Power Device#1 is in the conducting mode, while Power Device#2 is held switched OFF.

4) This situation connects the upper tap of the transformer to ground via the power device#1, which in turn causes the battery positive to pass through upper half of the transformer, energizing this section of the transformer.

5) Identically, in the next instant when the pinB is high and PinA is low, the lower primary winding of the transformer becomes activated.

6) This cycle repeats continuously causing a push-pull high current conduction across the two halves of the transformer winding.

7) The above action within the transformer secondary causes an equivalent amount of voltage and current to switch across the secondary by means of magnetic induction, resulting in the production of the required 220V or the 120V AC across the secondary winding of the transformer, as indicated in the diagram.

DC to AC Inverter, Repairing Tips


In the above explanation a couple of things become very critical for obtaining correct results from an inverter.

1) First, the generation of the oscillations, due to which the power mosfets are triggered and the process of voltage induction is able to take place across the winding of the transformer.

2) The second important factor is the frequency of the oscillations, which is fixed as per the country’s specifications, for example countries that supply 230 V, generally have a working frequency of 50 Hz, in other countries where 120 V is specified mostly work at 60 Hz frequency.

3) Sophisticated electronic gadgets like TV sets, DVD players, computers etc. are never recommended to be operated with square wave inverters. The sharp rise and fall of the square waves are just not suitable for such applications.

4) However there are ways through more complex electronic circuits for modifying the square waves so that they become more favorable with the above discussed electronic equipment.

Inverters using further complex circuits are able to produce waveforms almost identical to the waveforms available at our domestic mains AC outlets.

How to Repair an Inverter


Once you get well versed with the different stages normally incorporated in an inverter unit as explained above, troubleshooting becomes relatively easy. The following tips will illustrate how to repair DC to AC inverter:

Inverter is “Dead”:


Check battery voltage and connection, check for a blown fuse. If that’s OK, open the inverter outer cover and do the following steps:

1) Locate the oscillator section; disconnect its output from its preceding stage and using a frequency meter confirm its proper working. No frequency or a stable DC indicates a possible fault with the stage. Check its IC and the associated components for the remedy.

2) In case you find the oscillator stage working fine, go for the next stage i.e. the current amplifier stage (power mosfet). Check each device using a digital multimeter. Remember that you may have to completely remove the mosfet or the BJT from the board while testing them with your DMM. If you find a particular device to be faulty, replace it with a new one, and check the response by switching ON the inverter.

3) Sometimes transformers also become the major cause for a malfunction. You can check for an open winding or a loose internal connection in the associated transformer. If you find it to be suspicious, immediately change it with a new one.

Although it won't be that easy to learn everything about how to repair DC to AC inverter from this chapter itself, but definitely things will start "cooking" as you delve into the procedure through relentless practice, and some trial and error.

Still have doubts...feel free to post your specific questions here.

Need Help? Please leave a comment, I'll get back soon with a reply!




Comments

  1. i have an Inverx 650 VA inverter overload at no load inverter.by mistake the phase output line connected to input phase supply after that the mosfet IRF 740 fleshed away after changing them only two were short circuited the inverter goes to permanently overloading at no load with red light i have no diagram for refernce.replacing the whole line Mosfet's in parallel or something else.

    ReplyDelete
  2. It would be difficult to guess without actually seeing the issue...so I am sorry can't figure out the problem from here.

    ReplyDelete
  3. Greetings Swagatam,
    My inverter has burned up a capacitor and the board specifies a different cap than the original, should I change the cap to the requirement printed on the board or just us the same original was 250V 470uf board has 450V 330 uf printed on it in this location

    ReplyDelete
  4. Greetings Steven,

    It's not critical according to me, you can use either of them, as per the availability.

    ReplyDelete
  5. Hello,
    I have a Go Power 1500 inverter and was using 4 - 6v AGM batteries to power the RV. The inverter when turned on goes into it's start up procedure and when finished it goes immediately into overload. I installed 4 new (same) batteries and it continues to do the same thing.

    I disconnected the inverter when the issue first happened and the batteries swelled and started smelling so I removed those too.

    Is there a component inside the inverter that would make the inverter revert to overload even with brand new batteries and everything else is fine?
    No tripped GFCI, or inline fuses blown etc.

    I didn't open the cover and inspect for any burnt components yet and the inverter itself doesn't smell like a capacitor etc. has burned.
    Is there anywhere that repairs these as Go Power doesn't repair their units so, I was forced to buy another inverter!

    Thanks in advance.

    ReplyDelete
  6. An overload situation might occur only under two conditions, if the connected battery voltage is much higher than the specified limits, or if the output load exceeds its predetermined level.

    As long as the battery voltage is correct and output is not over loaded, even 100s of batteries connected in parallel wouldn't cause any issues or tripping.

    So, there's certainly some other serious issue with your inverter, not something which you can diagnose at home.

    ReplyDelete
  7. Ok, understood on the non home diagnosis of the unit. Where can I send it for repairs and what is the labor charge usually to repair it? I realize parts would be a cost too.

    Go Power doesn't repair their own units as mentioned prior.

    Thanks in advance.

    ReplyDelete
  8. I am sorry, I really do not have any information regarding this.

    ReplyDelete
  9. The power devices (mosfets) are the ones which might have got damaged, according to me

    ReplyDelete
  10. Hi Swagatam. My 5000W 12V to 230V PSW inverter's fan speeds up as the temperature of the unit rises (or as the amp draw increases, not sure which is the case). At lower speeds it will slow down as load or temp decreases, but if it reaches top speed, it gets "stuck" there and never returns, running at high speed, unless the unit is shut down and powered up again. How can I fix this to have it always return to lower speeds when it cools down?

    ReplyDelete
  11. Hi Andries, it will be difficult to diagnose because different models have different circuit topologies, and configurations, which are unique to those models, so it's not possible to troubleshoot without practically seeing it.

    ReplyDelete
  12. Hi, i have a 2500 watt 12volt/240volt inverter, on the same system i also have a generator which takes over when the batteries are low. I have 2 rotatry switches operating the electric, however as expected i turn the generator power while the inverter power was also live thus putting 240 volt power to the 240 volt supply from the inverter.
    This tripped the breaker on the generator and although i have reset that the inverter now does not work.
    It has illuminations lights on it, it makes a pulsing noise and there is a slight smell of burning although the fan still works.
    What do you think? (not of me lol but of the inverter please)!!

    ReplyDelete
  13. Hi, although im not very sure, if the smell is from the inverter while it's in switched ON positioned would certainly indicate a damaged tramsformer winding, but if it's happening in OFF position then it would need some investigation to see exactly what's burning (lol)....most probably it's the inverter winding that might have gotten slightly damaged due to the generator voltage in-surge.

    ReplyDelete
  14. I have in the motorhome a 1000 W 12v to 220V (240) inverter which produces no more than AC 200 V from the 85 Ah leisure battery. On the engine switched on it goes down to even 183 V. Please advice what could be an issue

    ReplyDelete
  15. your batteries could be producing lower than optimal voltage or may be are not fully charged.

    you could try verifying the same by replacing them with new batteries.

    ReplyDelete
  16. My issue with a ready-made inverter is not considered here. From the beginning, this inverter worked fine for charging, but always made capacitive-input devices behave erratically when plugged in. The trackpad on the laptop doesn't move the pointer on the screen properly, and has a lot of jitter. Problem disappears when the device is unplugged from inverter. And perhaps more dangerously, a particular USB charger plugged in the 120V outlet (I know it's an inefficient use of the inverter ;) gave me a discharge from touching the metal case of the tablet. This charger doesn't have any issue when plugged in at home, even though the mains is ungrounded. Maybe it was the charger or simply static electricity build-up on me from repeatedly moving to and from the driver's seat.

    Still, how would I know what could be at fault in this case? I have no oscilloscope to verify the waveform or possible spikes, though I'll see if I can build a USB one.

    ReplyDelete
  17. Selim, are you sure the inverter is generating the correct RMS voltage? you can confirm it by checking the output voltage with a multimeter set at AC 250V range.

    If it shows over 150V, the high voltage could be causing the issues.

    Or it may be due to the high amount of harmonics from the inverter.

    Try adding a 0.22uF/400V capacitor right across the inverter output terminals and check the results.

    Inverters normally do not have a neutral, they have an alternating phases coming out of both their outputs pins, that's very unlike our mains AC, this could be the cause of the slight shock that you are getting from the charger body.

    ReplyDelete
  18. Hello sir, i have a microtek inverter which was working nicely from couple of year but suddenly i got one problem......sometime its stop working and indication show for overload and fuse blow while its output load and fuse are ok......and when i restart the inverter then its working again......what is the reason behind this

    ReplyDelete
  19. hello my life,
    it seems to be an internal circuit problem, which needs to be diagnosed by removing the circuit board and checking with a multimeter,,,,it would be difficult to troubleshoot by assuming.

    ReplyDelete
  20. Off grid small house system. The inverter is feeding 40v AC back over the 12v batteries. In this state, current positive terminal to ground is 8 u Amps, as measured with a multimeter. This is making 12v backup generator live to 40v ac and zaps someone when they go to start the generator. Also the 40v ac appears to be interfering (but I'm not certain) with various charging cycles from solar and wind controllers. Can you give some clues as to further fault-finding techniques or suggestions please?

    ReplyDelete
  21. I guess the 40AC is connected with the battery through a bridge and a voltage regulator, in that case the battery could be safe, but a human could feel the zap due to his body earth passage.

    You can try isolating the 40AC to the battery section via a transformer, the primary could be rated at 40V and the secondary slightly above the battery voltage rating.

    ReplyDelete
  22. ...a schematic could have helped to understand the situation in a better way.

    ReplyDelete
  23. Hello sir, i have a microtek inverter which was working nicely from couple of year but suddenly i got one problem....wen i start it or increase load on it...... it starts generating abnormally high sound and output voltage i very low but at that tym it blows CFLs and mobile chargers....... after few minutes it will behave normal

    ReplyDelete
  24. Hello Sharad,
    The automatic voltage correction feature of the inverter seems to be malfunctioning, it will need to be diagnosed practically, can't suggest much without inspecting.

    ReplyDelete
  25. Hii I have a 800VA Inverter & 150Amp Battery attached to it. My inverter is not showing the charging signal and indirectly charging it by overcharging the battery. Few days ago I topped up my battery by distilled water and after that I found out that the battery is not charging and over that when check with tester current is being shown on both the terminal of the battery.
    Plz let me know about the problem and give me some solution for it.

    ReplyDelete
  26. Hi,
    I used my 300W inverter (12Vdc to 230Vac) to power a double tube flourescent light fitting. The total wattage of the light fitting is 130W. The tubes lit up, but then after switching off the light fitting and then switching it back on, the inverter failed. There is a red LED indication on the inverter which means that there is a fault. What could I have blown? Could the high inrush current have blown some component, or could a switching surge have blown some component? What is the most likely component in the inverter that could fail due to the inductive load which I subjected it to?
    Please reply soon, Riyaz

    ReplyDelete
  27. try charging the battery with an external battery charger unit and then connect it with the inverter, the fault could be with your inverter's charging system.

    If the battery doesn't charge optimally through an external charger it would indicate a damaged or a sulfated battery and will need to be changed

    ReplyDelete
  28. Hi, Normally a good inverter will not fail even if its outputs are short circuited, so a tube light should have noway affected its operations.

    Can't say what might have happened to it without a practical examination, looks like a part failure inside..

    ReplyDelete
  29. Sir i want to make a 850va inverter at home i am studying but did not get idea please provide me a complete circuit diagram with component list.my id is raj100386@gmail.com thanks

    ReplyDelete
  30. Rajesh, do the assembly as per the given diagram, the IC is 4049 the transistors are made up of TIP122 and TIP35 pairs....the capacitor value is 0.01uF, the resistor value near the capacitor is 100k, the transistor base resistors are 10k each

    ReplyDelete
  31. Hello sir howcr u....
    My problem is that i m having a luminous 800va inverter 150amp battery attached to it...it's charging led were not working...so when i was repairing that board..it touched in heat sink of mosfet...after that none of the led's are working...it's not a big issue but....main problem is that inverter giving low output voltage 150 volts...on load and on no load...i measured it's battery charging amperes...which is 12amps...i tried different battery but problem is same....are mosfet's blown up??? If yes how can i check them with multimeter....???

    ReplyDelete
  32. Hello nitin, if the output is low then it could mean a few of the fets are fried or working asymmetrically...check the amp without load by connecting an ammeter in series with battery positive...if it's high without load would confirm a serious fet malfunction

    ReplyDelete
  33. Hello sir...there are two series of 5-5 mosfets each in my inverter...so one mosfet was looking cracked...so i changed whole series of 5 which was chn 608 with chn 347...when i connected battery it was working...but whenever i put load on it...,it started switching power on off immediately...and its relay started making noise...i remove load...after few minutes...a mosfet fried again with a pop sound...and a little transistor 639 started smoking....can u determine what's the exactly problem ???
    Wish u a happy diwali...

    ReplyDelete
  34. Hello Nitin, I think the oscillator stage is frozen in your inverter which is causing the mosfets to short circuit through the trafo winding....disconnect the mosfet and the power buffer stage from the board and check whether the oscillator is working or not.

    ReplyDelete
  35. Ok sir...i m gonna try it...and let u inform...

    ReplyDelete
  36. Hi Roger, I think the overload protection circuit could be malfunctioning, try to locate the overload cut off relay or the particular circuit section, remove it and then may be you can try troubleshooting the possible fault in it.

    ReplyDelete
  37. sir I'm jeylani,
    I'm beginer bt I've interest to learn abt designing of ckts pls guide me

    ReplyDelete
  38. Jeylani, you can start posting your specific questions in this blog, I'll reply with solutions...

    ReplyDelete
  39. Sir Iam B.V.R
    I have DC TO AC 200W pwr inverter(12V DC to 220V AC)(50HZ),I wanted to use this by solar pwr,So how much capacity of CCU and BAttery I can use in this circuit

    ReplyDelete
  40. Bathula, a 50 AH battery will do the job, however for much longer backup you can opt for a 100 AH or higher batteries.

    ReplyDelete
  41. hell sir,
    my home inverter doesn't give output. when mains power cutoff, inverter indicates on position but, could't give output. battery rating 12V, 135AH. how can i identify the fault, how to solve the problem or how can i repair.....???

    regards
    Sushant

    ReplyDelete
  42. Hello Sushant,

    there are two things which might be causing this problem:

    battery power not reaching the inverter, battery not charged or the relay changeovers are faulty and not transferring the relevant power lines across the output

    ReplyDelete
  43. Hi! Hope you are doing fine. Can you help me with my power inverter? I have this TBE 1000W power inverter that was working fine until it made this long beeping sound. I removed it from the solar panel system and connected it directly to the battery and it still is making the beeping sound. The battery is fine because it is being used in another solar panel system. What could be the problem? Thanks in advance!

    ReplyDelete
  44. Hi, I am sorry it would be very difficult to diagnose or judge an internal fault of a system, because there could be several reasons for a particular faults, not possible without practically checking it.

    ReplyDelete
  45. Hi,

    I have a Silverline 1000W inverter that made a smell and stopped working!

    A visual inspection showed a pin burned and the IC plastic cracked on the SDC 7500 chip.

    I was going to solder a DIL socket in and try a new IC but I can't seem to find one online.

    Also would you know what sort of fault further downline might have taken this chip out. Its the Vcc pin 12.

    It seems to be a difficult IC to source?

    Would you have a circuit diagram of this inverter?


    Your comments greatly appreciated,


    Kev

    ReplyDelete
  46. Hi, I compared the pinouts of your inverter IC with a more commonly available IC TL494 and they looked exactly similar.

    So I think you can try replacing the burned SDC7500 with a TL494 and check the response.

    However I can be difficult to understand or judge the actual reason behind this damage, because normally the supply to the electronic stage is always regulated and through a step down transformer.

    I have a simple inverter version which is comparable to the one that you are using, if you have previously built electronic circuits then probably building this one from the start won't be a problem for you, here's the design:

    https://homemade-circuits.com/2015/05/simplest-pwm-modified-sine-wave.html

    ReplyDelete
  47. Hello, could you tell me in 3 lines what is the main difference between repairing inverter and non inverter air condition ? I do not find an easy explanation to tell to someone else. Thank you.

    ReplyDelete
  48. An inverter in an air conditioner is used to control the speed of the compressor motor to drive variable refrigerant flow in an air conditioning system to regulate the conditioned-space temperature.

    By contrast, traditional air conditioners regulate temperature by using a compressor that is periodically either working at maximum capacity or switched off entirely

    ReplyDelete
  49. hi i have an inverter which indicating faulty yet i have replaced all the mosfet with new one what might be the problem pliz assist.

    ReplyDelete
  50. without sufficient tips regarding the inverter circuit and the fault it would be difficult to judge the issue...

    ReplyDelete
  51. Good day,
    I've got a IR series pure sine wave inverter with 48volt system. I only notice this last week where my inverter shows a 9% constant load from 6pm to 6am (night time) even if I turn off all switches in DV box. Thus no electricity flowing yet shows a constant 9% load. Yet before it jump to 9% constant load for night time - the normal load is 1%-3% at 5pm. Any idea what might be causing this. Thank you in advance

    ReplyDelete
  52. Although it would be difficult to judge without testing it practically, any circuit that might be associated with the output winding of the inverter transformer could be malfunctioning and leaking power....you can try temporarily removing the connections of the circuit associated wit the output of the trafo and see if the issue rectifies, otherwise it could be something more serious.

    ReplyDelete
  53. I am an electrical engineer but not so much into inverter. Your problem made an interesting reading so thought of of understanding it more.
    We need to confirm that
    1.0 There is no load being fed by circuit not routed through distribution box.
    2.0 Confirm the working of indicating meter by using clip on ammeter, before and after 5 PM. Measurement should be done at output wires from inverter to box.
    3.0 In case clip reading donot change in correspondence with panel meter, we may doubt problem inside inverter.
    4.0 during daytime, switch off all load and confirm meter reading.
    These observations may lead us in understanding the problem

    ReplyDelete
  54. What would happen if the AC and DC "collide" within the power inverter? The inverter is connected to solar batteries, and it is used as an alternative to power the lighting in our house. But someone turned both the main circuit breaker for the lighting, and the alternative circuit breaker "on". The circuit breaker connected to the power inverter and the solar batteries got "tripped". When i turn off the main circuit breaker and turn on the alternative solar circuit breaker, it is not working. It seems that the power inverter got broken when the two circuit breakers were turned on at the same time. Is there any way to fix the inverter?

    ReplyDelete
  55. If DC is connected with a same potential AC, then the during the negative cycle of the AC, their would be an explosion or a short circuit, burning both the DC fuse (if any) and the AC fuse (if any).....if the DC potential is much lower still their would be an explosion and short circuit for both the cycles...if DC potential is much higher still their would be an explosion for both the cycles....but nothing can be confirmed without a practical investigation

    ReplyDelete
  56. What do you suggest on doing? Should I change something on my inverter or is it permanently broken and I have to get a new one?

    ReplyDelete
  57. if there are any fuses in the middle you can check those whether or not those are burnt and replace them....or check the relevant voltages before the circuit breakers to see if the circuit breaker was the only device which might be damaged and possibly change those with new ones.

    ReplyDelete
  58. Sir this anbarasan iam interesting to service inverter i already sent my request but no response once again i request in 850va inverter mosfet explide after change mosfet abnormal heat produce in the mosfet heatsink is there driver problem please reply me

    ReplyDelete
  59. I have already answered to your earlier comment, you can find it in this article:

    https://homemade-circuits.com/2012/04/how-to-check-mosfet-using-digital.html?showComment=1437282049692#c5075736144765103392


    inverter is a huge subject, it cannot be learned by just referring to a diagram or an article, you should learn it through an institute

    ReplyDelete
  60. hi can you know the replacement of this chip ic( 1203 LNK36GN OE245B ) it was blown and no available on electronic stores

    ReplyDelete
  61. sorry I could not find any info regarding it, online

    ReplyDelete
  62. hi my inverter is only putting out 185 volts why is that( 16 batteries connected)

    ReplyDelete
  63. please provide more details...

    ReplyDelete
  64. Hi Swagatam, I have an inverter ( 300W Meind ) which short circuits when I give power to it to power on. When there is no fuse, it doesn't do that. When the switch is ON, it trys to BEEP for low power.

    It had a blown capacitor which I replaced it with a higher vlotage. ( 16 to 25 )

    There are no blown or burnt components.

    Please help me, I don't want to spend more money on buying another inverter.

    Thanks!

    ReplyDelete
  65. Hi Parsa,

    I am sorry, it would be impossible to judge the fault without practically checking it.

    ReplyDelete
  66. I have a 2200W inverter to provide back up power for a sump pump. The inverter goes into overload (and blows an inline 15A 125V fuse) every time anything is plugged into the output plug.

    This particular inverter is designed to plug into wall AC to keep the batteries charged and pass through 'wall' power when it is available. When power goes out it switches to battery power and inverter mode to power my sump pump.

    Whether the unit is passing through 'wall power' or in 'inverter' mode as soon as anything is plugged into the ouput outlets there is a 'buzzing' / 'vibraton' and an overload condition. It seems like there is a short occurring when anything is plugged into the outlet.

    What could be the problem? I am not sure where to look for the shorted condition ... transformer? Why would it only short when something is plugged in... and why would it short when passing through current from the wall as well as when producing inverted power from the batteries?

    Note - this unit used to function normally.... so it must be a worn or failed part / condition.

    ReplyDelete
  67. I think some internal circuit stage might be malfunctioning and shorting the output possibly through a relay, on detection of a load.

    You can troubleshoot it by tracking and locating the "load" wires which may be terminating from the trafo output, and temporarily disconnect everything that might be associated with these wires....after doing this you could check whether the problems persists or not...if still it continues to behave in the same manner then the problem could be assumed to be on the primary side....

    ReplyDelete
  68. Hello good sir,

    I have a 300W 12 V DC to 230 V AC Mascot Inverter in my boat, which supplies a tv-screen and an underwater camera. The problem is that most times the screen will not turn on, it just makes a ticking sound. But when I pull the plug and wait a couple of minutes with the engine running, it will usually start when I plug it in again..

    I measured the inverter inlet and it says 16 V, and the outlet is only around 190 Volts. Should it not be around 230 Volts? I have a 12 V 125 AH battery. I'm a rookie when it comes to electronics, so I hope you'll have an idea whats going on.. :]

    Regards

    ReplyDelete
  69. Hello Nozthis,

    It could be due to insufficient initial current for the inverter to start the load...you can put a switch in series with the load, and initially keep it switched OFF....you can switch it ON once the inverter and the engine has gathered enough strength.....or alternatively you can upgrade the battery with a higher AH rated battery.

    ReplyDelete
  70. ...the drop in the voltage could be due to insufficient current from the battery

    ReplyDelete
  71. Hello Sir Swagatam,
    My inverter was affected by a thunder strike. It can still be powered on when the power cable is plugged. The heat sink is observed to heat up when power is being supplied but the inverter does not function anymore as before. The capacitor at the end near the power supply line is tested with a multi-meter and seen to be ok. There are no visibly burnt components on the panel (motherboard) when closely inspected. How do I fix this problem?

    ReplyDelete
  72. Hello Chinda,

    It would be extremely difficult to judge the fault from here, because s thunder lightning can be so powerful that even if it brushes-of an electronic circuit, the small sensitive devices could get damaged permanently without getting burnt.

    It wouldn't be a wise idea to speculate without practically checking it.

    ReplyDelete
  73. Hello Mr.Swagatam
    I have 500w inverter which I use with car battery and by mistake I placed the positive (catch) with the negitive bettery output and placed the negative (catch) with the positive bettery output
    Since then the inverter is not working.
    I wonder whats the problem and how do I fix it?

    ReplyDelete
  74. Swagatam Sir, Good Evening :)

    I have luminous inverter UPS LB 800 VA and been using it for last 7 years. Now it doest not charge battery althogh smart charging LED blinks. smart charging LED remains blinking despite main power cut. Battery is functional as other inverter charges it well.
    Sir your immediate reply is solicited and thanking you in advance.

    ReplyDelete
  75. Hi Amar,

    you can check the voltage across the charging output points, and also the current available from it.

    voltage can be checked using a multimeter on DC V range, while the current can be checked by selecting the DC 10 Amp slot or the highest amp range in the meter,

    If the output is absent or is too low you can assume something's not correct in the circuit or may be the output power device is blown.

    ReplyDelete
  76. Hi Swagatam, My inverter shows battery low in 10 mins time, I have checked the distilled water in the battery and filled it. I worked fine for 2 days and back to the same. What should I do ?

    ReplyDelete
  77. Hi Dan,

    is your battery too old? anyway you can confirm the condition of the battery by removing it from the inverter and by checking it with an appropriate load, if it shows quick discharging symptom or if it shows sluggish response while getting charged you can assume it to be dead or in a bad condition....

    ReplyDelete
  78. Im just a kid don't know much about electronics. The thing is my inverter fuse keeps blowing up in seconds after changing it to more powerful ones. What can i do? The input voltage isnt high. Its usually around 220v

    ReplyDelete
  79. sorry, it would be difficult to judge the fault without a practical look....may be you'll be able to trace it someday once you have grown up and learned adequately about electronics....

    ReplyDelete
  80. please guide me the difference between narrow and wide switch function?

    ReplyDelete
  81. couldn't understand your question....

    ReplyDelete
  82. hi sir m using microtek 800 va ups its not giving back up out put.i hv checked out put winding of transformer.the windings are ok but showing no supply.please tell me probable fault.

    ReplyDelete
  83. Hi Satyendra, the fault could be hidden in the circuit board section and difficult to judge without a practical assessment, so I am sorry it won't be feasible to detect without checking.

    One common reason could be a blown fuse, or a burnt wire...you can check for these.

    ReplyDelete
  84. The 800 VA inverter has 40A orange coloured fuses on the board. Please check these four fuses for integrity. These are located on board.
    Also check that toggle switch for vacations is not in off position. If it is in off then LCD display shows trikle charging by flickering filling nozzle.
    Please check that battery is healthy
    Also ensure that inverter has s switched on as indicated by small green LED.

    ReplyDelete
  85. Good day, sir.
    I have a Coleman Inverter PMP3000. I made a mistake when I connected on a reversed polarity. All fuses are busted. I changed all the fuses with new ones but when I connected it again with the right polarity, all the fuses got busted again. What is likely the cause of the busting of fuses? Please advise. Thank you very much. God bless.

    ReplyDelete
  86. Good day benz, it's surprising that your inverter did not have a reverse polarity protection, anyway now it seems it's been damaged quite a lot, and the internal power devices could be burnt.... you'll need to open it completely and check the power devices using a multimeter.

    ReplyDelete
  87. Thank you very much for your reply,sir. Yes, it has no reversed polarity protection;
    I opened it and so far my ocular inspection shows NO sign of burnt out power devices, resistors, capacitors,etc. Looks clean and net in all its parts. I haven't used the multimeter as I give this feedback, I'll complete first ,then I'll inform you. Thanks again,sir.

    ReplyDelete
  88. thanks Benz, electronics can never be confirmed with mere eye inspection :), you'll need a multimeter for this...fuse blowing off even when connected correctly indicates that the output devices are most probably burnt or shorted.

    ReplyDelete
  89. Good evening sir,
    I have a Schumacher 1500 watt inverter that was mistakenly connected to the 12 volt battery backwards ( + to -) and (- to +). There was an audible pop sound and then nothing. After connecting properly still no response. From your experience is this likely to be repairable? I have very limited experience or knowledge on the subject but I'd like to know if there is a chance of repair.
    Thanks,
    Randy

    ReplyDelete
  90. Hi Randy, your inverter problem appears to be similar to Benz's inverter problem....it's really surprising how the manufacturers missed the reverse polarity protection, which is extremely important in such equipment which require external battery connection.

    anyway, the problem is definitely repairable.

    you could probably follow the positive line and check the stages which are being connected with this line.

    Most probably you would find this line going to the PCB of the inverter which might be having many associated ICs and other devices...so you could check whether these ICs are directly involved with the positive line or not, if yes, then it would imply that these devices could have been damaged due to the wrong battery connection.

    ReplyDelete
  91. Dear sir,
    I am using micortek EB 850 inverter gor last 4-5 years. Today I found Mains to UPS mode is not working. In mains power supply mode displaying full charge (New battery just 2 months old) battery in display, Once main power supply is off, all display light off in inverter, and no power output also.
    I have checked the fuse, it is OK.
    I have checked there is no loose connection also.
    Please help.

    Thanks & regards,
    Suman Rana

    ReplyDelete
  92. Dear Suman,

    The problem could be in the change-over driver section which could be operating through relays or mosfets or IGBTs...this section might not be transferring or switching in response to the detected power failure.

    so this section will need to be traced and troubleshooted, perhaps one of the driver transistor could have gone faulty.

    ReplyDelete
  93. Dear Sir,

    I have a 5000w power inverter. When you switch to inverter use, it begins to beep although battery is not weak. When you turn on the charging unit to charge battery, it beeps as well. What could be the cause and how can this be fixed.

    Thank you.

    ReplyDelete
  94. Dear Nikki,

    It would be difficult to locate the exact fault without a practical check up, but broadly it could be due to a faulty part in the low battery sensor circuit stage or a bad solder point in this stage

    ReplyDelete
  95. Dear Sawagatam,my UPS Infosec x3 2000 one side 4 FET burnt. I replaced all four. Opposite side all four ok. But still UPS not works and display shows 0 with continous beep.

    ReplyDelete
  96. I am sorry Ali, it would be difficult to judge the issue by imagining, it'll need to be diagnosed practically

    ReplyDelete
  97. Thanks for the quick reply Brother ! i would like ask for learning and understanding in this UPS. four FET one side and four FET opposite side, In each side 2 FET are insulated with layer with heat sink and other two each side without insulated layer piece.what is the logic? And battery charging how happens? with which rectified dc voltage and from where?

    ReplyDelete
  98. Dear ali, again it would be difficult to judge unless and until it's actually and traced from top to bottom because inverter circuits come in many different varieties with specific configurations, so all have their own exclusive design and operational methods

    ......for the battery charging your UPS must be deriving the input from your mains AC, even if a transformer is not included it could through an SMPS circuit stage.

    ReplyDelete
  99. Hello Swagatam. I have a 2.4kva (24v) inverter system with 2 batteries of 12 v (100A) each. I have noticed recently that after a full charge, the low battery alarm comes on in like 5mins but power may stay up to 7hours with the alarm. Please kindly advise.

    ReplyDelete
  100. Hello bassey,

    I think the low voltage detector stage has gone faulty or the preset adjustment could have been affected or the preset itself has become faulty...you may check for one of these issues.

    ReplyDelete
  101. Hello Swagatam,

    I have a Hyundai 3.4kw inverter generator (HY3600SEI). The generator engine starts first time and runs up to speed. The green AC ready light comes on for about 3 seconds and then go's off (power is removed from output socket) and the Red overload light comes on and stays on.

    If I apply a load (any size load up to 3400 watts) within the 3 second time frame that the generator starts and energizes with green light (Power available), the load will power up and run for hours producing power. If no load is applied, red light comes on and power is no longer available without turning off engine and restarting.

    Any idea's?

    Thanks
    Warren

    ReplyDelete
  102. Hello Warren, it appears like the inverter is equipped with a "no load cut-off" feature and that's a good feature to be included in the system.

    I think you should keep the load connected initially and switch ON the inverter in this position to bypass the concerned feature?

    and possibly connecting 3400 watts may not be crucial, you can try with a 100 or 20 watt load and check the response., it should do the trick.

    ReplyDelete
  103. Hello Swagatam,
    i have been following the conversations you have had with different people with different questions, i am really impressed with your intelligence and willingness to help other people, thanks.
    However i have my own problem which believe you will help.
    My inveter is 500 watts and i use it for only the TV which is 100 warts and 3 energy saver bulb 12 watts each. Now my inverter is working but the green light is off and the voltage gauge is down, what could be the problem and what are the dangers if possible any suggestions for fixing the issue?

    ReplyDelete
  104. Hello Swagatam,
    In connection with the question i asked, i am using the battery i am using is 12 V and it is 100AH

    ReplyDelete
  105. Thank you Joseph, the pleasure is all mine:)

    If your inverter's power output related operations are normal, then the failure of the indicators cannot be considered as a critical issue....it could be simply due to a damaged part or so in the indicator circuit stage which might be affecting its working....you can check the specific stage and change the faulty part after locating it correctly that will hopefully solve the problem for you....

    ReplyDelete
  106. my inverter is showing a short circuit warning. i have checked all mosfets. they are in good condition. what might be the reason. can u help me about the common circuits for shortcircuit detection or help me to find the damaged component

    ReplyDelete
  107. try disconnecting the wires that are terminating to the transformer from the mosfets and check the response....you can also try connecting an ammeter in series with the battery positive and check the current....if it's high at switch ON would indicate a short, or else the warning could be assumed to be a false or malfunctioning.

    ReplyDelete
  108. hi Swagatam I have an inverter that just installed in my car and with direct connect to the battery with aligator clips. when I plug in a small 230V radio in the inverter. the radio comes on and then goes off again constantly. I know it is not a faulty radio. it works in a normal house plug. Do you have any suggestions on this?

    Thanks

    ReplyDelete
  109. Hi Nik, the problem could be due to the very small load presented by the radio, which is prompting the inverter's "no load shut off" feature to activate....try using a 100 watt bulb and see whether the issue still persists.

    ReplyDelete
  110. Hi
    I have suoer inverter 2000W the output is 219 vac but the fan is not working. what is the problem????

    ReplyDelete
  111. Hi, check the voltage across the fan wires, if it's OK then the fan could be faulty, otherwise the circuit which is responsible for producing the voltage could be faulty.

    ReplyDelete
  112. Hello sir.i have a ups Lebanon make.3700va,.it's now beeping n indicating inverter off/charger on from time to time.what might be the problem n what's the remedy for that.?
    Thanks in advance.

    ReplyDelete
  113. Hello Jack, the "mains to INV" changeover relay stage could be malfunctioning, open the inverter and check the relay stage which is responsible for implementing this changeover, and check the transistors or the IC associated with the relay switching action.

    ReplyDelete
  114. or may be your battery has become defective, check the response by replacing it with a fully charged new battery

    ReplyDelete
  115. Hi Sir, if I charge my phone and iPad this does not happen but the moment I put on my 120w TV my 900va Indian inverter based on MOSFET technology trips into Low battery with alarm and goes back instantly to invert and power the TV.

    Sometimes I will have to off and on the inverter a few times before it works. What could please be the issue, is it the inverter or battery as battery reads between 11v - 13.5v

    Thanks in anticipation.

    BILLY

    ReplyDelete
  116. Hi Sir, My inverter goes into Low Battery modend instantly goes back to normal inverting when I put on my 120watt TV. Sometimes it will go into Low Battery and will not recover until I off the inverter and on again. Meanwhile my battery still reads 11v - 13.5v and when it works, it gives me backup up to 14 hours.

    Can it be the inverter or the battery that has problem? Kindly assist.

    ReplyDelete
  117. Hi Billy, It will be difficult to pin-point the fault but surely it's around the "battery level detector" stage....could be a bad solder point on the IC leads, you can check it and re-solder the points and check the response.

    ReplyDelete
  118. hello sir,
    i've 850 su kam inverter. its problem is that it does not charge batter when mains is on and when it is in inverter on mode it doesn't shows mains. also when mains is 220 volts the inverter outputs is just 96v. again on inverter mode the output is 220volts
    i changed the relay...but problem is same
    plz reply me

    ReplyDelete
  119. Hello Amit, it looks like there's some kind of loose connection in the wiring, check all the connectors especially the wires which are coming from the transformer to the output socket, and also the connections between the relay and the transformer.

    Clean the PCB with a brush and check if all the solder points near the changeover relay are fine.

    ReplyDelete
  120. swagatam sir..... microtek sine wave inverter shows over load on load n keeps on buzzing ... i changeD the relay the connecteions were damaged ... still ot shows over load on no load n keeps on buzzing.... is that the function ic problem or else??

    ReplyDelete
  121. Aqib, try checking the stage which is responsible for activating the relay, it could be an opamp which is configured to sense overload and could have gone faulty and might be causing the relay to trip...therefore locate this opamp or whatsoever stage it may be and check the reason behind its malfunctioning, and possibly replace the faulty part with a new one....

    ReplyDelete
  122. Good Morning Sir,

    I have recieved a lebanon made inverter to repair that has one transfo (used for both charging and DC-AC ivertion), Six mosfet (IRFP250n) each three are in parallel, Inverter board, A big relay close to the transfo and Battery charging ciecuit.
    The inverter is not working. I check it following the guidlines you provided above and I found out that, the inverter can work when 220 AC power applied to it but it cannot work on battery.


    The foulties area are summarised bellow..

    1. It cannot charge the battery while the transformer has provided the DC voltage through the help of the Big relay.

    2. If battery is connected, a relay on battery charging board is moving.

    3. Also, there are two big resistor of about 10 or 15watts connected in parallel that spilt into pieces (unfortunatelly it has no details on it, I would have change it and try the inverter) but, when I arranged it and apply AC power I can see the charging LED lighting. But to me, I think this resistors are what prevent inverter to accept the battery, because they are working as a trigger.

    1) Sir could you please suggest what is wrong?
    2) And, what type of the resistors should I try?

    Thank you Sir.

    ReplyDelete
  123. Aminu, it will be extremely difficult to judge the faults without a practical check up...so I won't be able suggest much.

    for the resistors, you can replace them with 12V flashlight bulbs and check the response for the time being, if it works then you can experiment with may be a 100 ohm resistor initially, and see its effect on the performance.... and modify the value accordingly.

    ReplyDelete
  124. Sir,
    I did not find the 100 ohms, but I found a pair of 300 ohms 20watts and 330 ohms 10watts.I connected each pairs in parallel and I tried each but the pair of reaistors are getting too much hot and smoky. If I leave it for some time, It charge the battery.

    Sir is there some solutions?

    thank you very much.

    ReplyDelete
  125. Aminu, disconnect the battery and then check whether the resistor becomes hot or not, if yes then it's not correct and might need further investigation, if the heating stops then you are probably in the right direction, and can try checking the path of these resistors up to the battery and assess the cause of the heating up of the resistors.

    ReplyDelete
  126. Yes sir, the resistors are getting hot only if I connected the battery.

    ReplyDelete
  127. My inverter trips with overload indicator coming on when power fails, it continues in this condition even when all load is disConnected and the inverter is reset. But strangely, functions well if I disconnect it from the mains and reset it even with full load connected.

    ReplyDelete
  128. there could be a related capacitor which could be linked with the mains supply and stays charged keeping the over load cut-off latched, as soon as the mans is removed this capacitor could be discharging and releasing the latch.

    ReplyDelete
  129. Please help me .whare can i find dspic inverter voltage datagram

    ReplyDelete
  130. Sir, but the overload tripping returns if the input is connected to main while no power supply is coming from the supply company

    ReplyDelete
  131. Sir, but the overload tripping returns if the input is connected to main while no power supply is coming from the supply company. Also, the overload happens only if the supply company stops the supply, turning the mains off does not cause tripping.

    ReplyDelete
  132. then it could be difficult to assess the fault because it appears that the neutral line of the mains is involved with the inverter operation, and connecting the plug could be connecting the neutral with the inverter and causing the issue...you may have to call a technician for a practical check up

    ReplyDelete
  133. I think the neutral line is somehow involved with the issue...

    ReplyDelete
  134. Sir,i have a 1.5kva inverter.My inverter shows short circuit on the dashboard but I have changed all the mosfets and even capactiors.i noticed that only 4 mosfts get hot on powers the inverter out of the 8 mosfets used.what could be thhe problem? thanks

    ReplyDelete
  135. Kenn, connect 12V car bulbs in series between transformer taps and the mosfet drains...and check whether the brightness is equal on the bulbs or not....if not then probably trafo could be damaged or malfunctioning...or may be the oscillator is not providing identical frequency across the mosfets...or there could some other hidden aspect which you can diagnose sing a DMM.

    ReplyDelete
  136. Thanks for ur prompt response.The brightness varies on the mosfets,also on isolation of the transformer,i still get the shortcircuit error on the dashboard.i cant see any physically damaged device,how do I find d oscialltor circuit & anyother means of troubleshooting it?
    thanks

    ReplyDelete
  137. If the short is showing even after disconnecting the transformer then I think the problem could be somewhere in the mosfet stage....you could try removing the whole mosfet stage and check the situation again by switching ON power....

    the frequency could be checked at the source which connects with the gates of the mosfets...you can use your DMM's frequency range for measuring the same.

    ReplyDelete
  138. i have removed the whole mosfet stagge including the drivers (Ir2110) but when I switch on I still get Short circuit on the dashboard.It really looks like a complex situation...Any Ideas?

    ReplyDelete
  139. since you have disconnected the whole circuit now it should be much easier to find the shorting locating, you can do it by using a multimeter or by connecting a series bulb with the input and then by disconnecting the remaining stages one by one until the bulb switches OFF.

    ReplyDelete
  140. i am repairing a invertec v270, i already replace the open capacitors with a new one. checked the fuse, diodes resistors and transistor but still there is no input.

    ReplyDelete
  141. sorry, that would be difficult to judge without seeing

    ReplyDelete
  142. i am having o-general inverter split air-conditioner two year the outdoor timer board was
    faulty, i am changed. it is working for past two years.now i am got fault the timer board.
    the indoor unit blink two times means , the o-general enginneers says, the outdoor timer to be changed.they says. how the timer board will get frequentlyfaulty?
    .

    ReplyDelete
  143. 2 years is quite a long period of time and things can get faulty within this period, change it once more and this time tell the engineers to show you what exactly they are changing and also confirm the operating parameters of the unit....and do not give them the old module....keep it with you and check it afterwards whether it was really faulty.

    ReplyDelete
  144. Hi swagatam
    I have a sukam 750va inverter. for the last few days its giving unique problem whenever i connect only a ups through it, ups starts giving fast tic tic sound of relay and when i connect it to a power point which isn't through inverter, it works fine. and when i switch on a tubelight or a fan ups' relay tic tic sound instantly stops. what could be the possible reason . i have measured voltages through and without inverter it's almost same. however when i measured dc voltage which charges the battery it was 13.9v instead of 12. please help me in this ... thanks

    ReplyDelete
  145. Hi Suresh, it will be difficult to understand the issue without checking it practically....but the 13.9V is not bad, it's correct for charging the battery.

    ReplyDelete
  146. Hi, I've a sine wave 2000W inverter. It has started showing bt in its display. What could be the possibility? I'm unable to get any help right now.

    ReplyDelete
  147. Sorry, it would be difficult to diagnose without a practical testing.

    ReplyDelete
  148. The problem could be with your fan and or with your inverter, most probably it could be with your inverter....I think the output harmonic filter circuit might be malfunctioning, an involved capacitor might have gone short or faulty.

    ReplyDelete
  149. I just have 12VDC 1000W inverter. I connected to a battery 100AH. It gives me 230V to power my lights and fans.When the battery runs down. I powered down and stop the inverter. Second day I charged the battery to full capacity and I connected to supply power . It does not supply power again . What could go wrong? Kindly help.

    ReplyDelete
  150. check the current consumption by connecting an ammeter in series with the battery positive, if it shows zero then there could be a loose connection somewhere, or a fuse blown or other similar issue, it will need to be diagnosed with a meter.

    ReplyDelete
  151. hi dear my name is Daniel.
    i just started to repairing electronics today i received one inverter 12 volt DC 1000va hibride this inverter is showing fault 3 when i connect battery with it could you please help me in this what should i do for it repair ????
    your kind response is awaited
    Thanks

    ReplyDelete
  152. princefcole2@gmail.com, SIR, I BUILT AN INVERTER WITH YOUR INSTRUCTION, USING: ONE = TIP35C, ONE= 4.7KOHM RESISTER, ONE =450V CAPACITOR, ONE= 230V TRANSFORMER AND ONE = 4007 DIODE, IT WORK, I GOT 120V AC, BUT IT CAN NOT PUT MY LAPTOP COMPUTER ON, WHAT SHOULD I DO NEXT? SIR,

    ReplyDelete
  153. Prince, which inverter circuit did you build? please provide the link

    the transformer wattage and the battery AH must be rated correctly as per the load wattage for it to function correctly

    ReplyDelete
  154. Hi Swagatam. I am sorry if I am posting this question as a repetition and maybe it was already answered. I connected my new 2000 KVA inverter today and fear due to a short circuit in wiring have busted it. (It showed a fault related to short circuit us well). Now ups is working only on main power supply only. As soon as I switch off the main, Inverter also dies instantaneously. l intend to repair it or alteast check for the fault myself. Can you please guide from your experience what can the fhoblem be. Many thanks

    ReplyDelete
  155. Hi, if you think you have shorted something while the inverter was in the battery mode, you can track the connections which connect the battery with the inverter devices and check for a possible shorting. initially remove the battery and check the resistance across these connections and check if it indicates a short, and keep following the lines until you discover the faulty part or the fuse or whatever may be responsible for the issue.

    ReplyDelete
  156. Hi Swagatham
    I have a 4 year old 850VA Sukham inverter backed up by a 150AH Exide Tall Tubular battery of the same age. Sometimes when the power goes off, the inverter immediately goes off to low battery. But when I checked the battery via a multimeter, it showed 12V. If I keep inverter off for some time( say 30 mins) and switch on the inverter it starts working properly(ie there is no low battery siren). In order to test if the battery was weak, I tested the battery by switching off the main power so that the inverter starts working. At that time the inverter worked properly for about 3 hours with lights, fans , TV switched on. I am not able to replicate this problem at will. So this is a random problem which happens. What could be the issue?

    ReplyDelete
  157. Hi Mells,

    Is this happening every time or occasionally? If it's happening randomly then the problem could be difficult to judge without a practical test.

    Most probably the problem could be in the battery charging controller section where the battery voltage monitoring circuit could be malfunctioning.

    your battery is OK for sure...the problem is in the charging controller changeover section

    ReplyDelete
  158. bina load k load show karta h inverter what is the fault could you tell

    ReplyDelete
  159. check battery current by connecting an ammeter in series with the battery positive, if it's normal or zero without load, then the fault could be in the indicator circuit

    ReplyDelete
  160. Hi Swagatham,

    I recently bought an Exide ECO 900 Inverter (Square wave inverter) and I am facing the below issues.

    1. The output voltage of Inverter shows 290V when I use it with 2 fans and one nightlamp, And the voltage getting drop to 250 to 260V only if I use more appliance at a time (3 Fans, 3 Tube light, 1 LED TV). And it is hard for me to use all these appliance at night while sleeping. I am scared since the 2 Fans are running too fast at night while using Inverter specifically having a Infant baby in my Home.
    Need your advice asap to get this issue resolved please.

    Thanks,
    Santhosh

    ReplyDelete
  161. Hi Santosh,

    The only quick remedy for this is to add a good quality electronic fan dimmer with the fans and reduce the speed appropriately.

    The other method is to use a lower voltage battery in your inverter, for example if the existing battery is rated at 12V/50AH, then you can replace with a 9V or 10V/50AH or 60AH battery.

    ReplyDelete
  162. Hi Swagatam,

    Thanks for your advice :-)
    Now I have add the Fan regulator to reduce the speed.

    I am already using a battery of 12V with 200AH to have more back up.
    May we have any other suggestion instead of replacing the battery, since I already spent a more on buying the above battery ? Also If I replace the low voltage battery, I doubt if I could use all other appliance at a time when needed.
    And adding a stabilizer from Inverter output will work out for this issue ?

    Also need to know is there any fault in my Inverter or this is the general character of Square wave inverter. If yes, i shall replace my inverter with the better quality one, since I bought the Inverter via Online only 5 days back, so I return it back as damaged product.

    Thanks,
    Santhosh

    ReplyDelete
  163. Hi Santosh, you can use a selector switch between the two batteries, when additional loads are connected you can switch to the 12V/200AH battery, and for smaller loads you can switch to the 10V/200AH battery.

    Your inverter could be without an automatic output voltage correction circuit which might be causing this issue, if you wish to have this feature then you can replace your inverter with a new one which has all these correction features built in.

    ReplyDelete
  164. Hi,swagatam.I have a ups using with my p.c.When there is main it gives 250 volt output;but during the mains off,it gives only 150 volt.I checked the battery is o.k.then what may be the problem?

    ReplyDelete
  165. Hi Alok, how did you check the battery.

    It needs to be checkered while its operating the inverter...connect an ammeter in series with its positive, and a voltmeter across its +/- terminals...the readings should match the load requirement specs, if not then your battery could be faulty and needs to be replaced

    ReplyDelete
  166. i have a modified sine wave inverter that can has a maximum rated power of 1000w, now i was messing around with it and trying to connect it to my room (from an electrical port with an on-off switch) but i forgot to turn the switch off and as a result it connected to the main house electricity and thankfully i only blow one my electric switches but i managed to get it back running using a spare plug-in cable, and now my inverter will turn on with fault, switch to power for a second then back to fault instantly and permanently, what possible cause that made the inverter goes like that? what is the possible issue/broken part inside it?

    ReplyDelete
  167. where did you accidentally connect AC mains in your inverter? normally the AC would be required for charging the inverter battery...so I can't visualize where exactly where you might have applied mains by mistake.

    ReplyDelete
  168. the house electricity was accidentally mixed with my modified sine wave inverter electricity and as a cause the switch broke and the inverter stopped working, it was from the 220v output from the inverter, and i direct plug it to the house electric outlet by accident

    ReplyDelete
  169. in that case the secondary winding of the trafo could have got damaged if it's a ferrite trafo, and due to the sudden AC influx there could have been a back EMF on the primary side damaging the fets....so the fault could be significant and needs to be diagnosed deeply.

    ReplyDelete
  170. Hi, what kind of charger are you using? does it contain some kind of critical sensing circuitry? because if the charger is a simple power supply then this should not happen, may be your charger's sensing circuit is detecting something in the inverter and not allowing the battery to charge while it's connected.

    also make sure the inverter is not consuming anything from the battery while it's idle..check this by connecting an ammeter in series with the positive wire which connects the inverter with the battery (+)...if it's not consuming anything then it's fine and you may try a different charger unit and see the response

    ReplyDelete
  171. Hello Mr. Swagatham
    I have truepower 850va square wave inverter,I want to replace its pcb
    with sukam torque pcb 900va so I want some help to buy the correct
    components which will protect my appliances from burning out. So can you help me to get the specs of the components which are circled in the red color from attached photo.
    I hope to check this link to know what I mean:
    https://disqus.com/home/channel/engineering/discussion/channel-engineering/how_to_install_sukam_torque_pcb_on_truepower_inverter/

    ReplyDelete
  172. Hello Ahmed, it's not properly visible...please specify what those components are?

    ReplyDelete
  173. Motherboard is changed to a new one for Sukam Smiley 1400 VA inverter. Later just on connecting to batteries & without even connecting to load it showed: overload. The repaired person told it has to be adjusted & taken back. Is it the same or due to board incompatibiliy

    ReplyDelete
  174. the technician is probably right, there could be some internal settings in the board which are not correctly adjusted and needs readjusting, and therefore it needs to be taken to the workshop and corrected

    ReplyDelete
  175. I bought a normal pure sine wave inverter and a separate solar charge controller. the power in my country 3 hours off then 2 hours on then 3 hours off then 2 hours on, the power keeps running in that pattern. To protect my battery I have to turn off my inverter to prevent charging from inverter but my question is that, is there any relay could do the following job: when power is there inverter charge the battery and solar charge controller stop working but when power cuts off, solar charge controller start charging the battery

    ReplyDelete
  176. you can try the following concept:

    https://homemade-circuits.com/2015/10/solar-panelbatterymains-changeover.html

    ReplyDelete
  177. Is there any way to reduce ceiling fan buzz when using square wave "truepower 850va" invereter?

    ReplyDelete
  178. you can try including an LC filter network at the output of the inverter and check if that helps

    ReplyDelete
  179. If mosfets are faulty inverter will still working?

    which capacitor film should I need to connect it to the output of TP850VA square wave inverter?

    ReplyDelete
  180. Nope, if power devices are faulty the inverter will smoke or shut down, it simply cannot work

    try a 0.47uF/400V capacitor

    ReplyDelete
  181. HI i just bought a 150 A battery . I have 800 VA inverter which when plugged in with the mains even though the battery is fully charged , my meter runs faster than when plugged in on mains solely.
    What might be the problem?

    ReplyDelete
  182. IS BTA16-600B THE EQUIVALENT OF BTB16-800CW?

    ReplyDelete
  183. Hi, check the current consumption by connecting an ammeter in series with the battery positive...this will show whether or not the meter is showing the correct response or some other hidden issue.

    ReplyDelete
  184. almost similar except some features

    ReplyDelete
  185. 1) MY TP850VA HAS BTB16-800CW TRIAC BUT IN MY COUNTRY IS NOT AVAILABLE SO THERE IS NO DAMAGING IF I USE BTA16-600B?

    2) IS IT SAFE TO RUN MY LCD TV ON MY INVERTER (SQUARE WAVE INVERTER)?

    3) CAN YOU PROVIDE ME A LINK FOR 0.47uF/400V capacitor? BECAUSE WHEN I SURFED THE NET I FOUND THAT X CAPACITOR IS THE RIGHT TYPE FOR MY NEED?

    ReplyDelete
  186. 1) yes you can replace it with the mentioned triac
    2yes it is safe.

    3) search for 474/400V capacitor you will find it.

    ReplyDelete
  187. Hi Swagatham,
    I have 850VA inverter. The AC input fuse keeps blowing whenever I switch on my iron box Even when its not on inverter i.e. when the power is there. I have tried with higher rating fuse however it didn't worked.

    Now I have placed a changed over switch to bypass inverter. Can you help?


    ReplyDelete
  188. Hi, I think the problem is with your ironbox not the inverter...do this:

    open the inverter and connect a second temporary fuse at the socket where you are plugging in the iron, and check whether or not this fuse blows....if it does then your ironbox may be faulty....for a changeover switch, the connections from this socket can be used with a 30 amp DPDT switch for the required modification

    ReplyDelete
  189. I searched electronic shops and I find 474k/630V, is it ok to use instead of 474/400V

    ReplyDelete
  190. sorry, that would be difficult to judge without practically checking it...

    check the output of the transformer which goes to the load.. may be there's some kind of shorting.

    ReplyDelete
  191. 630 is better than 400...so no issues you can use it.

    ReplyDelete
  192. Hello sir

    I have a 16w rechargeable fan but 2 resistors of its pcb were burnt out, I went to a repairer and changed those 2 resistors but the pcb doesn't charge the battery so can you help me to fix that, the following link https://drive.google.com/file/d/0B_2QrDIghjN1Z3RZSHRsVzlrb00/view?usp=sharing has a pic of pcb and the red circle denotes to those resistores. the battery is 6v7ah

    ReplyDelete
  193. Hello Ahmed, please check the entire line which connects the supply source to the battery via the PCB, check which part is not allowing the current to pass to the battery, simply replace it with a new one.

    ReplyDelete
  194. My dad has gudlite inverter 1400va when the battery gets full charging indicator stops blinking and fan will stop working but after 2 years when the battery gets full, charging indicator stops blinking but fan will work for 2 hours, is there any problem with the inverter?

    ReplyDelete
  195. the transistor which is utilized for driving the fan could have gone faulty...check it and if possible replace it with a new one

    ReplyDelete
  196. I have Su kam inverter for household use. It suddenly got dead in night i also checked the fuse. fuse is perfectly right

    ReplyDelete

Post a Comment