Make a 100 Watt LED Floodlight Constant Current Driver

You might have probably come across these fantastic high power, high efficiency LED modules and wondered how do you make these? Here we learn how to make a 100 watt LED flashlight out of it?

Introduction

The article revises the datasheet of this LED module and explains a simple driver circuit which can be used for operating it safely for the intended lighting purpose.

So far we have learned about LEDs with rather smaller features and applications. However the present article finds out how a LED module in the order of 100 watts can be actually used for illuminating a house at costs probably 5 times lower than the conventional lighting devices.

 100 Watt LED Module Image


100 watt led image


We have all studied a great deal about LEDs and about their high-efficiency with power consumption. The LED technology has helped us to design and incorporate very high intensity light installations at minimal consumptions as compared to the other conventional form of lighting concepts.

Lower power consumption also means low heat emissions, which again is an added feature and helps to keep the crucial issue of global warming at bay when LEDs are utilized.

As days pass by, technology keeps on improving and we are able to witness many incredible and unbelievable results with these outstanding lighting devices.

The 100 watt LED module is one such marvel of modern science which has created a breakthrough in the field of LED lighting.

Not surprisingly, the device is able to generate an astonishing 6500 lumens of light intensity at a consumption of mere 100 watts, but the interesting part is the size, which is barely 40 square mm.

The saving made by these devices is estimated to be five times more than any other form of light producing device and the if we compare the specified intensity of 6500 lumens, that corresponds to an excess of 500 watts light power that might be acquired from a halogen lamp.

Let’s discuss the important specifications of this amazing LED in brief and in such a way that even a layman understands:

100 Watt LED Datasheet and Specifications


Typically the preferred color is white, as that produces the most favorable and desirable illumination for all applications.

The power consumed is 100 watts for optimal performance.

The emanated heat for the specified white color is up to 6000 Kelvin.

The intensity of light generated with the above specs is a staggering 6500 lumens.

Typical operating voltage of the device is around 35 volts.

The current required for producing the above light intensity is around 3 Amps.

ESD level is safe and very high up to 4000 V.

The safe operating temperature level is very wide, ranging from minus 40 to 110 degrees Celsius.

The optimum angle of viewing is also wide, up to 120 degree.

Dimension of the unit is truely mini, the height being 4.3 mm, length 56 mm and width 40 mm only.

The specification narrated are sufficient for illuminating a 20 square meter space amply, almost at flood light levels ….. baffling.

Main Features of the 100 Watt LED


The advantages include the following:

High power light output without degradation even after long usages.

Highly robust mechanical specifications, involving less wear and tear and high resistance to changing atmospheric hostilities.

The overall performance is consistently optimal throughout the operating life.Having discussed the above features of the proposed 100 watt LED lamp, it would be interesting to also learn regarding a useful recommended circuit that may be used for driving or operating the device at safe levels.

How to Make a Current Controlled 100 watt LED flood Light Circuit

A simple two transistor, powerful current limiter, LED driver circuit, which can be used for converting the above discussed device into a 100 watt LED flashlight or to be more accurate, a floodlight is described below:

The circuit of a 100 watt LED flood light shown below has been discussed in few of my other articles also, due its versatile and rather straightforward design; the circuit becomes very suitable in places where current limiting at low costs becomes an issue. Though the discussed designs mostly dealt with low current applications, the present circuit is specifically intended for handling high currents and up to 100 watts and more power.

Circuit Diagram

transistorized current controller circuit for LEDs


Looking at the figure we can see a couple of transistors are coupled together such that the base of the upper transistor T1 becomes the collector load of the bottom transistor T2.

The upper transistor T1 which actually carries the LED current is quite vulnerable itself, and is not equipped to control the amount of current through itself and the LED.

However since the base current of this transistor decides the amount of collector current that can pass, it simply means that by restricting its base current to some safe specified levels, it might be possible to keep the overall consumption within tolerable limits.

A current sensing resistor connected at the emitter of T1 is used to convert the current consumed, into a potential difference, across it. This potential difference becomes the base trigger for R2.

However as long as this voltage is below 0.6 volts or simply below the minimum forward voltage drop of T2, T2 remains unresponsive, but once it starts exceeding this value, triggers T2 which in turn clamps the base voltage of T1, rendering it inactive.

This instantaneous cut off of the base drive to T1 shuts the LED for some fraction of a second, bringing the current and the potential drop across the current limiting resistor to zero. This action reverts the circuit to its original stance and the LED is again switched ON.

The process repeats a number of times per second to keep the LED and the current to safe and precisely tolerable limits.

The value of R2 is calculated in such a way that it keeps the potential difference across itself below 0.6 volts until the LED current reaches 100 watts, after which the restricting process begins.Warning: The LED must be mounted on a correctly optimized heatsink as per the specifications provided in its datasheet..

How to Calculate the Current Limiting Resistor

For calculating R1 you may use the following formula:

R1 = (Us - 0.7)Hfe/Load Current,

where Us = supply voltage, Hfe = T1 forward current gain, Load current = LED current = 100/35 = 2.5 amps

R1 = (35 - 0.7)30/2.5= 410 Ohms,
wattage for the above resistor would be = 35 x (35/410)  = 2.98 or 3 watts

Formula for calculating R2 is:

R2 = 0.7/LED current
R2 = 0.7/2.5 = 0.3 ohms,
wattage may be calculated as = 0.7 x 2.5 = 2 watts

Current Controlled 100 watt LED Lamp complete schematic

adding current controlled to a customized 100 watt led bulb




Need Help? Please leave a comment, I'll get back soon with a reply!




Comments

  1. Hi, yes it is doable.

    T1 and T2 are transistors, for your application you may use TIP31 for T1 and 2N2222 for T2.

    As per your LED specs the other component values could be as follows:

    R1 = 270 ohms, 1 watt

    R2 = 0.7 ohms 1 watt



    ReplyDelete
  2. Your calculations and assumptions are perfectly correct, in fact I have aready discussed the idea elaborately here, you can refer it for better understanding:

    https://homemade-circuits.com/2013/06/universal-high-watt-led-current-limiter.html

    ReplyDelete
  3. ...a 1% MFR type resistor will do the job.

    ReplyDelete
  4. I respectfully request you to explain what's incorrect in the above formula and diagram....if you are unable to do it, you can learn it from me further, don't worry I will apologize you for your above ignorance.

    ReplyDelete
  5. I have not built this circuit yet, but you can try TIP35 for T1 and TIP31 for T2

    ReplyDelete
  6. Hi Swagatam

    I could not see my post (in the hobby circuits) as well as your reply, which I have been notified in my mail box!

    Anyway, please check and confirm if following components would be okay for supplying fixed 5A to the load from a car battery:

    R1 = 68R 2Watts
    R2 = 0.14R 3.5Watts
    T1 = TIP41 (6A)
    T2 = TIP31 (3A)

    ReplyDelete
  7. Hi Abu-Hafss,

    Which posts are you referring to?

    Yes the calculations are approximately correct.

    ReplyDelete
  8. The T1 heat up very quickly ...but i only tested at 12v/18A, maybe the low voltage or the high amps cause the T1 to heat up? I used T1,T2 mje3055, R1 390R and R2 0.5R (3w both). Thanks.

    ReplyDelete
  9. Hi Swagatam

    I referred to the post wherein you recommended me LM338 for fixed 5A supply from car battery. By the way, what would be wiring of LM338 with car battery?

    As for this circuit, will it be possible to use it as variable current controller? If yes, how?

    ReplyDelete
  10. yes, when voltage is low, current will be high, you can try TIP35 with heatsink for getting a better response

    ReplyDelete
  11. Hi Abu-Haafss,

    I have no idea what happened to that comment, may be due to some kind of glitch in the system.

    Please refer to the following article, you can go for the first circuit shown there:

    https://homemade-circuits.com/2013/06/universal-high-watt-led-current-limiter.html

    ReplyDelete
  12. I have a 10W LED flood light that I purchased off Ebay. The manufacturer states that the LED itself has a forward voltage of 9-11V with a max current consumption of 1050mA. I do not want to use it at the full current. I'd like to keep it below the max around 900mA. I'd like to be able to do 2 things with it once it is converted over. 1) Use it as a standard flood light on my vehicle and 2) Have the ability of making it flash like an emergency light. Can I use a 2N2222 for T2 and what resistor values do you recommend ?

    ReplyDelete
  13. I think you should use a LM317 IC for your application, the above circuit is crude and should be used only for those applications which does not support the available hi-tech ICs due to high voltage/current parameters.

    You can try the first design shown in the following link:

    https://homemade-circuits.com/2012/11/3-watt-5-watt-led-dc-to-dc-constant.html

    For making it flash, you can use a standard IC555 astable circuit and connect its output pin3 to the collector of the 2N2222.
    When you switch ON this circuit, will result in flashing of the LEd.

    ReplyDelete
  14. I need Constant Current Driver circuit for 12Volt,20Watts and 10watts LEDs kindly share the simple diagram

    ReplyDelete
  15. you will have to use an smps for this, there's no simple circuit for it

    ReplyDelete
  16. hello! i have 6watt led from ebay and data is 9v-12v dc. @ 380mA. each. i want to run 6-12 of this led at a time. What should i use in the circuit? or, can you kindly make a circuit for that? is it possible to run these led with transformerless power supply? please! Help me. Thanks. :)

    ReplyDelete
  17. capacitive type of power supply will not work with these LEDs.

    The easiest way is to procure a good quality 12V/2amp SMPS and drive all the LEDs in parallel with this unit.

    ReplyDelete
  18. Can you show me the mentioned circuit? Please???? I want to make 12v/2amp SMPS. will you kindly show me how?

    ReplyDelete
  19. you an make this circuit:

    https://homemade-circuits.com/2012/03/how-to-make-simple-12-v-1-amp-switch.html

    just upgrade the secondary winding from 1amp to approx 2amps by using two parallel wire instead of one. Wind these two wires simultaneously.

    ReplyDelete
  20. I have a 10W LED which has a forward voltage of 9-11V with a max current consumption of 1050mA. Can I run this LED with 7809.

    ReplyDelete
  21. Hi there!

    I recently bought a 100W LED which has 34V forward voltage and 3A forward current. What kind of transistors should I use in my case?

    ReplyDelete
  22. Hi,
    you can use TIP3055 for T1, and TIP31 for T2

    ReplyDelete
  23. Hello Swagatam Majumdar. Very good website and very useful !!!!

    I buy one of this 100w led cool white , But I looking at the datasheet, I do not understand WHICH IS BETTER VALUE OF CURRENT AND VOLTAGE for maximum brightness is achieved without damaging the LED (with heatsink and fan).

    I read IF= 3,5 A

    Min 32

    Typ 34

    Max 36


    I THINK 3,5 IS MUCH CURRENT BECAUSE P=V.I=34V . 3,5 A = 119 W.

    THIS I HAVE: i.imgur.com/DBCJNuI.png

    I LIKE BUILD A LIMIT CURRENT A OUTPUT VOLTAGE REGULATOR.

    COMPONENTS AND VALUES THAT RECOMMENDED BUY ME TO GET THE MAXIMUM LED LIGHTING WITHOUT BREAKING IT???? ( I WILL PUT IT WITH HEATSINK AND FAN)

    MY IDEA IS PUT 34V- 3A OR 33V-3.2 A

    but i dont know values ​​using of T1, T2 , R1 AND R2 AND POWER OF THESE what can you tell me??


    THANK YOU VERY MUCH

    REGARDS.

    ReplyDelete
  24. Hello Harley,

    I think you should go for 32V as it looks very optimal, safe and within the reach of an LM338 circuit which I would be referring to you, the above circuit could be relatively crude so I don't recommend it.

    You can use a 0-24/5amp transformer, rectify it using a full bridge rectifier and filter the output with a 1000uF/50V cap.

    Apply the above output to a LM338 current limiter circuit and use the output from this circuit to illuminate your LED. This would provide an ultimate guarantee to your device....however do not forget about adding a heatsink to the LED.

    The LM338 circuit is shown in this link:

    https://homemade-circuits.com/2013/06/universal-high-watt-led-current-limiter.html

    use the first design, replace LM117 with LM338 and calculate R1 from the given formula

    ReplyDelete
  25. ....a 0-24V after rectification would output around 34V, which is just suitable for your application, the rest will be handled by the LM338 circuit

    ReplyDelete
  26. Hello Swagatam, really amazing tutorial.
    I am new in the world of electronics and would like to know how to wire a 0,12A cooling fan so that it is powered by the same 12v battery that powers the led.
    Thank you for your time.
    Best regards.

    ReplyDelete
  27. Hello and thanks for your fast response.

    I I already bought Power DC-DC Boost Converter 150W 10-32V to 12-35V 6A .

    You mean it does not serve me this dc-dc boost.

    I have little knowledge and no clear to my this mounting.

    IS THIS CORRECT?

    i.imgur.com/965TvoC.png


    IF I CHOOSE OPTION DOWN THE VALUES ARE TIP3055 for T1, and TIP31 for T2

    R1 = (32 - 0.7)30/3

    = 313 OHMS

    wattage for the above resistor would be = 32 x (32/313) = 3.3 WATTS

    Formula for calculating R2 is:

    R2 = 0.7/LED current

    R2 = 0.7/3 = 0.23 ohms,

    wattage may be calculated as = 0.7 x 3 = 2.1 watts


    IF I WOULD LIKE THE OPTION 1 CIRCUIT HOW FINDING VALUES?


    SORRY FOR MY LITTLE KNOWLEDGE.


    REGARDS FRIEND.




    ReplyDelete
  28. Harley, the connections shown in the image are perfect, if the boost converter is able to provide the required current/voltage, everything would work satisfactorily.

    I would recommend the IC current limiter over the above transistorized version because it's much sophisticated in all respects.
    However if you are interested to go for the above, you may do so.

    The calculations that you have made are also correct.

    ReplyDelete
  29. Thanks Miha.

    You may do it by simply connecting the motor wires parallel with the battery poles, observing correct polarity

    If the motor is rated at a lower voltage, you may use a regulator IC such as 7805, 7806, 7808, 7809 etc whatever may suit your motor.

    ReplyDelete
  30. dear sir i want to flash sequentially/(running mode) 4 to 6 nos of 3w color leds from 12v dc source. request circuit instructions.

    ReplyDelete
  31. Dear Jayanath, you can try the following design:

    https://homemade-circuits.com/2011/12/simple-yet-effective-led-strobe-light.html

    First construct the shown design successfully using 5mm LEDs, later I'll explain how to modify it for illuminating high watt LEDs

    ReplyDelete
  32. ok sir i will do and let u know thanks

    ReplyDelete
  33. Dear Sir,

    Thanks for the setup, could you pls tell the value of T1 and T2. Also in Ebay its advised to give 32 to 35V , Approx 3500mAh. In this stage, i guess 32V is feasible right. Can you please suggest a best transformer-less circuit with best filter with zener protection.

    Awaiting for your valuable feedback, thanks in advance.

    ReplyDelete
  34. Dear Anish, you will have to procure a 32V/3amp SMPS and use it with the above circuit for driving the LED

    ReplyDelete
  35. I would like to try a 50 watt version and a 30 watt version, would you change the R value for each curcuit?

    ReplyDelete
  36. you can take the help of the following article and the given formulas:

    https://homemade-circuits.com/2013/02/make-this-1000-watt-led-flood-light.html

    ReplyDelete
  37. By way of the DC boost converter that utilizes the much higher, reversed polarity fly back voltage from its inductors collapsing magnetic field whilst its oscillating at high frequency. That higher then source and presently AC voltage is then rectified back to DC at the desired higher voltage. Pretty simple stuff when you look at the schematics for any boost/buck converters...

    ReplyDelete
  38. How can you vary the brightness of 100 watt led?

    ReplyDelete
  39. use a variable resistance for R2

    ReplyDelete
  40. Great blog.

    Question: what do u use for T1 and T2? Url? Any heatsink requirements?

    Question: are R1 and R2 axial resistors?

    ReplyDelete
  41. thanks, heatsinks will be required for T1/T2 depending on the load dimension.

    R1, R2 could be axial or any other variant doesn't make any difference.

    ReplyDelete
  42. Hi, I have a workshop and would like to run 5 x 50w led flood lights in a row,
    they would be run from a 240v output genarator.
    Can I run them from one driver/transformer or does each LED need a separate supply?
    I am out of my depth when it comes to making one so I will have to buy what I need.
    Could you please advise me on what I need to get.

    Many Thanks

    ReplyDelete
  43. Hi, you can run all the 5 modules from a single adequately rated power supply unit, preferably an SMPS unit.

    In between each LED and the supply you will need to insert a current controller stage as shown in the first diagram of the following post:

    https://homemade-circuits.com/2013/06/universal-high-watt-led-current-limiter.html

    LM117 will need to be replaced with LM338

    ReplyDelete
  44. HI! Like the others; Great site, and thanks for sharing your knowledge! But I wish you could have been a bit more specific this time. An amateur tinkerer like me has no idea what transistors to use. I can build stuff from schematics, and cross reference if I don't have the recommended transistors, but I need to know where to start looking in my scrap box...

    I'm experimenting with a similar LED to the one in the picture. I rescued it from a dumpster, so I don't have the specs, but a quick test showed that it works. It has five rows of ten LEDs, and after googeling a bit it seems that that means it's a 100W unit, right? And if so, what would you have used for T1 and T2?

    On behalf of noobs the world over, please enlighten us!
    (recommendations for 50W and 200W+ setups are also most welcome... :-)

    ReplyDelete
  45. Hi, thanks

    you can use TIP3055 for T1, and TIP31 for T2, these transistors would also work for 50 watt and 200 watt lamps :)

    ReplyDelete
  46. I want to power a 10w led using a 12v lipo batter, i wanted to use the 2nd circuit that you mention here: https://homemade-circuits.com/2012/11/3-watt-5-watt-led-dc-to-dc-constant.html I want to also make that flash like emergency lights. I saw that you mention on the comments here for a guy to use "IC555 astable circuit" is that what I need to use, if so, how do I hook it up in the circuit, and where do I purchase it, or can I just do a google search for "IC555 astable circuit"
    thank you for your help.

    ReplyDelete
  47. yes you can use any standard 555 astable flasher circuit and drive the LED from a BJT stage connected at pin3 of the IC.....such as a TIP122...connect its base with pin3 via a 10k resistor, emitter to ground (negative) and the LED across collector of the transistor and positive supply.

    The battery poles may be then connected to the input of the LM338 circuit and the output of the LM338 to the pin4/8 (positive) and pin1 (ground) of the astable....positive will also connect to the LED as explained above

    ReplyDelete
  48. thank you for your reply, can you tell me what is a BJT, kinda new to this, is there any way you can post a quick wiring diagram of how you are telling me to hoke it up please

    ReplyDelete
  49. you may refer to this article which is quite identical to your requirement:

    https://homemade-circuits.com/2012/09/led-emergency-light-circuit-using-boost.html

    R1/R2 should be 47k each and C1 = 10uF/25V

    the supply points would need to be connected with the output from the LM338 circuit.

    L1 could then be replaced with the specified LED

    ReplyDelete
  50. Hello,
    I'm from India. I will be using 5x100W LED lights as my video light from AC 250v/50Hz source.
    I'm currently using Halogen Lamps (Work Light) for my video cameras made by "Simpex" and bulb made by "Halonix". It is 1000W. Best part: It does not create any flicker in my video footage.
    If I make a LED video light what will be the modification to the circuit and would it create any flicker in my footage? If it does it would ruin my footage. What about the Heatsink? And I need LED of a colour temperature nearly 2800K to match my Halogen is it possible?

    ReplyDelete
  51. Since the LED lamp would be run on Dc it would generate zero flicker or interference, so it would work better than a halogen lamp.

    The above circuit is s cheaper alternative, although it's reasonably accurate I would recommend you to buy a current controlled 33V / 15 amp SMPS unit for operating the LED modules.

    The LEDs would definitely need heatsinks, it would include a back base with appropriate slot to facilitate clamping of the modules with large aluminum plates for the required cooling.

    ReplyDelete
  52. Mr. Swagatam Majumdar, Thanks for your quick reply.
    Where can I find such an SMPS in Chandni Market, Calcutta, as I am in Calcutta?
    What would be the approximate cost of that SMPS?
    I need your assistance for one thing. Please bring a camcorder DV/Digital-8 or any from someone for one day and test different footage with a single 100W white LED and check whether it creates any flicker or not. Warm white would be better since they are nearly halogen like yellowish (3200K) while halogens are a little more yellow, 2800K 18000 lumen.
    Be sure to keep the shutter speed at 1/50. Also test whether there is any flicker at a higher shutter speed e.g., 1/100, 1/250, 1/500, 1/1000 etc.
    I'm interested in the above circuit since it would be a lot cheaper and a viable alternative to halogen/HID for everyone.
    These days halogen based lights are annoyance in an air conditioned conference room, closeup shots, small room, summertime shots. So LEDs are the way to go. Please update me after testing.
    Thanks.

    ReplyDelete
  53. Mr. Pinaki,

    regarding the SMPS you may have inquire in the local electronic market, or you can buy it from any relevant online store

    If i get an opportunity I'll surely try out the experiment and let you know about the results.

    ReplyDelete
  54. Can I put a capacitor between the Vcc and LED junction so that the light does not flicker at all. What would be the calculation method for this capacitor and what would be the type of that capacitor, please give me an idea about it.

    ReplyDelete
  55. yes you can do it, calculating it is not necessary, the larger the value the better it'll get.

    perhaps a 2200uF/50V would be more than sufficient.

    ReplyDelete
  56. Sir how can I give 35v to the circuit through 230v AC main

    ReplyDelete
  57. Hi Swagatam, excellent tutorials you have made here. I have a confusion. I want to power a 10 Watt LED using a12 volt-3A adapter. In one comment you said
    "Make R1 = 40 Ohms and R2 = 0.2 Ohms for using a 10 watt LED @12V supply." and in another comment you said
    "T1 and T2 are transistors, for your application you may use TIP31 for T1 and 2N2222 for T2.
    As per your LED specs the other component values could be as follows:
    R1 = 270 ohms, 1 watt
    R2 = 0.7 ohms 1 watt".
    Which one is correct? And also is 0.2 or 0.7 ohms resistor available in market?
    Can I use TIP41 instead of TIP31? Any alternatives for 2N2222?

    Also, I bought a 20W LED floodlight few months back, it is now flickering very much. I measured the LED driver, the voltage is constant 42V but the current is varying for about every 0.2 seconds from 0.1A to 0.9A. The driver has a chip "PL3536", I think that is malfunctioning. Any ideas how I can fix it?

    ReplyDelete
  58. Basit, you'll need an smps driver for it, as shown here:

    https://homemade-circuits.com/2014/09/32-v-3-amp-smps-led-driver-circuit.html

    ReplyDelete
  59. Thanks Raj,

    The calculations were done as per the given formula, you can calculate the R1, R2 values as per your LED specs and confirm the results.

    However the above mentioned design is suitable for higher voltage drivers where an IC regulation may not be available, for your 10watt 12V purpose you can simply use a LM338 current controller as explained here

    https://homemade-circuits.com/2013/06/universal-high-watt-led-current-limiter.html

    although for a 42V driver the above circuit may be tried since an IC circuit could be difficult to find

    ReplyDelete
  60. Is the LM317 capable of driving a 10watt LED from 12volt?

    ReplyDelete
  61. The transistors can be TIP3055 for T1, and TIP41 for T2. both on large heatsinks

    R2 = 0.7/3 = 0.233 ohms, 3 watts

    R1 = 220 ohms, 5 watts

    ReplyDelete
  62. Hello Mark,

    you are right, 10k, 1/4 watt will do.

    BC547 is a BJT, and all BJTs require just around 0.7V to trigger across their base/emitter, so 5V is incorrect you might have interpreted something else.

    ReplyDelete
  63. i want to use the circuit for 50w..what changes should i make

    ReplyDelete
  64. what are the voltage and amp specs of your LED?

    ReplyDelete
  65. I have 12 battery and 12v,10w led bulp 5no's.that bulps are connected in parallel,the bulp takes 2amps,lm338 regulator using but heat is very high,so please give 12v DC to DC constant current and voltage drive circuit.

    ReplyDelete
  66. LM338 is the easiest option to go with....an SMPS could be quite difficult to build.

    Use a large heatsink with the IC and also with the LEDs, that will take care of the situation.

    Heating is a normal phenomenon, there's nothing to worry about it, just use a heatsink with maximum dimensions...

    ReplyDelete
  67. hello, I have a 36V 20W LED, what resistors that i need?
    T1:TIP31C, T2: MMBT3904

    ReplyDelete
  68. Hello Swagatam. I have a 20w led (36v and 0.525mA) what are the resistors that i need?
    be already in useT1:TIP31C, T2:MMBT3904

    ReplyDelete
  69. please calculate with the help of the given formulas.

    ReplyDelete
  70. Hy Swagatam, I am from Indonesia.. can you help me
    I want to make adjustable driver circuit for LED 100w (34v 3A) which can adjust the light intensity of 30 to 100%..
    Can you indicate what its circuit.?

    ReplyDelete
  71. Hi Mustafa,

    you can try the following circuit and adjust R6 for obtaining any desired illumination on the LED.

    https://homemade-circuits.com/2014/09/32-v-3-amp-smps-led-driver-circuit.html

    ReplyDelete
  72. hey sir
    ... your all project is awesome . i am using some circuit . sir i want a new circuit for 10watt LED through AC supply 220VAC (if any option to use 15 watt CFL Kit to make) or making new circuit for 10watt LED ... , THANKS FOR READING SIR

    ReplyDelete
  73. thanks rock.pro, I am glad you liked them.

    You will basically need an SMPS driver circuit for illuminating a 10 watt LED...you can try the following circuit and effectively use it for the same:

    https://homemade-circuits.com/2012/03/how-to-make-simple-12-v-1-amp-switch.html



    ReplyDelete
  74. Hello, if i need to control a on/off 10W 12v led with a 12v 3.3 battery with a reed switch, where do i need tu put it on the circuit?
    thanks

    ReplyDelete
  75. you can wire the reed across the positive supply and the base of T2...make sure to include a 1K resistor in series with one of the reed wires...

    (+)<--------(reed)-----^^^^^-------->base of T2

    ReplyDelete
  76. So i disconnect the base of T2 from the circuit and connect the reed like you said, or i leave the circuit like it is and connect the reed like you said?

    ReplyDelete
  77. Do not disconnect the base from its existing position, simply connect the reed to the base of T2 as explained earlier.

    ReplyDelete
  78. Can you explain theoretically how this will control de circuit if i connect the reed like you said?

    ReplyDelete
  79. when the reed closes it activates T2, which in turn grounds T1 base forcing the LED to shut off

    ReplyDelete
  80. But i want the opposite, i want the led to shut off when the reed opens, what do i need do do?

    ReplyDelete
  81. connect T1 base through the reed to R1, meaning the T1 base should connect to R1 through the reed...that's all.

    ReplyDelete
  82. So in this case i dont need the 1k resistor for reed right?

    For my 10w 12v led i will use a 12v 3.3A battery for supply and i will use for T1 TIP31C and for T2 2N2222A, can you tell me wich hfe value from datasheet of TIP31C i will use for R1 calculations?
    For this power of led will 1/4 resistor for R1 and R2 are enough?

    Finally are my choices forr T1 and T2 correct?

    Thanks

    ReplyDelete
  83. 1K with the reed will not be required now.

    TIP31 and 2n2222 will do for a 10 watt led.

    hfe is not critical, it can be any average value within the range of the device.

    resistor watt may be calculated as per the explanation given in the above article.

    ReplyDelete
  84. hi,
    can i have the circuit diagram for 5w / 10w Led's? it would be really helpfull.

    ReplyDelete
  85. mains operated or low voltage DC operated?

    ReplyDelete
  86. Thankx swagatam ,
    All the question and answer clarified all my doubts.
    Thankx for the share really very helpfull ...
    Keep up the good work .

    ReplyDelete
  87. Can you use pwm to control the input 12v to dim and leave the 470 alone as well?

    ReplyDelete
  88. 470 ohm is for protecting the transistor base...so it cannot be removed even with a PWM control..

    ReplyDelete
  89. Very useful tutorials. I searched the entire net to get a circuit for a 20v smd led. Can you please tell me which transistors and resisters should I use. The led specs. are :

    20w white color led
    Vf 9-12v DC
    If 2000MA
    Output lumens 1800-2000lm
    Operate voltage 9-12DC


    I don't know anything about electronics. Please help if you can :)
    Thank you

    ReplyDelete
  90. Thanks! You can do it by simply by connecting the above explained transistorized current limiter circuit stage with the output of any standard 12 V 2 amp SMPS AC to DC adapter unit, and then connect the LED at the position shown in the diagram...

    the value of R2 will be 0.6/2 = 0.3 ohms..2 watt

    ReplyDelete
  91. Thank you for the quick reply sir. Can I use TIP31 and 2N2222 for T1 and T2, as for 10w Led drive? And what should be the R1 ?

    ReplyDelete
  92. Please use the formula furnished for calculating the resistors.

    ReplyDelete
  93. dear swagatam sir

    we are using 32 watt cob led 12 vdc power supply current 3 amps the power supply is 12 VDC power supply but the led lights are getting hot and buring out the power is 12 vdc we have checked with the multimeter cand u please suggest will this circuit help in this case

    ReplyDelete
  94. Dear Marc, did you attach a large heatsink with the LED??

    Make sure you do this otherwise your LED will get damaged within a minute

    additionally you will need to introduce the above explained current limiter for your LED, or you can also alternatively employ the following current limiter which is much sophisticated than the above.

    https://homemade-circuits.com/2013/06/universal-high-watt-led-current-limiter.html

    also make sure to attach large heatsink to the transistors or the LM338 whichever is selected by you

    ReplyDelete
  95. dear Swagaram I have power supply from printer epson and gives about 36.4v I want to use for 100w led but am afraid that the led will burn,how can I set the voltage to 34volts can you help me what should I bild before the led chip

    ReplyDelete
  96. dear marinko, if you restrict the current to a safe level by the procedures explained in the above article then the voltage will automatically settle down to the LED spec...36V will not be an issue once the current is suitably limited.

    ReplyDelete
  97. Swagatam sir can you suggest me a 35v rectifier circuit for operating this driver.

    ReplyDelete
  98. Hi Keynon, you can use a 1N4007 for the rectifier if the current spec is below 500mA or 1N5408 if the current is below 2amp or 6A4 diodes if the current is below 5 amps

    ReplyDelete
  99. Thanx for your response sir. I'm going to used it to drive a 100 watt led. So 6A4 diodes would be suitable. So sir please suggest me a 35v power supply circuit.

    ReplyDelete
  100. the best option would be to buy a 12-0-12V transformer and use its end wires with a bridge rectifier and a 2200uF/50V capacitor to get around 34V DC output and then use this output in conjunction with the current limiter circuit explained above to drive your LED

    ReplyDelete
  101. ...converting a 5V to 35V would be unnecessarily lengthy and costly process...so not recommended.

    ReplyDelete
  102. Sir can you please give me the circuit diagram for the above 34V power supply.

    ReplyDelete
  103. keynon, please procure a 12-0-12v/3amp transformer first along with 4nos 6A4 diodes and a 2200uF/50V capacitor, then we can discuss further.

    ReplyDelete
  104. Hi Swagathm
    I have some doubts related with current controlled circuits. Please clarify.

    1) If I use a 35v, 2.5A SMPS , can I avoid this transistorised current control circuit ....? If voltage is constant current will also constant.

    2) As per your above circuit calculation , at 35v, LED current is 2.5A. Then at eg.30v and 40v what will be the current flow through the LED....?

    Thanks in advance.

    ReplyDelete
  105. Hi Anil,

    1) yes if the source current is limited to the safe level then there's no need of using the above circuit, you can directly connect the LED with your power supply.

    If the voltage is constant then the current will be also constant that's true but if the LED temperature rises it might start drawing more current from the source even with a constant voltage situation, that's why current limiting is essential.

    2) For a 35V LED its current consumption will become proportionately lower at 30V and proportionately higher at 40V....but if the current is restricted from the source then even at 40V the current will not go above 2.5A....

    ReplyDelete
  106. Hi, I have two TIP102 on hand and was wondering if they could be used with a 34v 3A 100w led. I calculated R1 to be 333ohm 5w. Does this sound about right?

    ReplyDelete
  107. Hi, yes it's OK to use them for the mentioned purpose.

    If you have used the formula exactly as given, by filling the parameters accurately then you can expect a correct answer...I do not have all the data so I am unable to calculate it myself

    ReplyDelete
  108. yes, it seems there was a mistake while calculating, that's the reason why I suggest everybody to calculate the parameters themselves using the formulas which are explained comprehensively, because I have to attend many many comments together and that can make me prone to mistakes..

    your calculations are correct if you did it exactly as explained in the article...

    ReplyDelete
  109. Hello, this site is awesome, thank you for it. I have 10 LEDs with a Vf of 3.75V and current handing of 1050mA. I would like to make a few different circuits as follows:

    1: run 3 of the LEDs using two 18650 size, 3.7VDC (4.2VDC when fully charged) Li Ion batteries connected in series.

    2: run 4 of these LEDs with the same battery setup

    3: run 2 of these LEDs using only 1 of the same batteries

    4: run 1 of these LEDs using 1 of the same batteries

    I would like all 4 of these circuits to maintain the brightness of the LEDs with fully charged batteries all the way through until they need to be charged. I would also prefer these circuits to include reverse polarity protection, battery over-discharge protection and, if possible, thermal protection. I would also like to fit them into a flashlight body if possible (I have a massive assortment of different sized flashlight bodies to choose from). I do have the ability to make and/or order completely custom PCBs and/or flashlight bodies if necessary.

    I know this is a lot to ask and I greatly appreciate any assistance you may provide to me.

    As always, thank you and have a great day! :-)
    -Mike.

    ReplyDelete
  110. Hi, I am glad you liked my site!!

    Can please you tell me why you need this variable LED light set up? and how do you plan to switch the LEDs, do you prefer to do it manually or should this happen automatically as the voltage drops.

    I'll have to address this design through a new article, so please specify the above data.

    ReplyDelete
  111. Hi, i have read a lot this post and called my attention.

    I bought a 30w 32-36v red LED light(i have burned a few LEDs before) and i want to make the led power supply. I tried and i can't do a good power supply to have the best performance from LEDs.

    I used 2 ideas to make a power supply:

    1) I have a 220 to ~36v AC transformer from old printer, and a rectified DC voltage around the 50v. The LED has a consumption of about 950 mA(enough from transformer). Besides i have two 2sc3320 from a bad pc power supply, and a few bc547... i tried using a 2sc3320 to make a simple dimmer(first LED burned) but didn't work.

    2)i had the idea to rectify from 220v ac... but i think that i will burn another LED

    So... wich idea is better to use? and how i can make a circuit for this LED power supply using the things i have?(except by resistors).

    Best Regards

    -Francisco

    ReplyDelete
  112. Hi, did you try the concept explained in the above article?

    Once the current is limited, the voltage is bound to drop to the preferred limit.

    so I would recommend you to use the above circuit with current limit set to 800mA.

    for the lower transistor I would recommend a 2N2222, but you can try 2sc3320 also...

    while calculating use the value "1.5" instead of "0.7" if you are using 2sc3320 for the lower transistor.

    ReplyDelete
  113. I thought I'd ask before try to use the circuit.

    So... there is no problem with voltage while the current is limited? I can put the LED safely in 50v dc with current limit to 800mA?

    ReplyDelete
  114. yes there's no problem, make sure to confirm the current by connecting a 10amp DC ammeter at the points where the LED would be connected....it must not show more than 800mA.....and mount the transistors on large heatsinks.

    ReplyDelete
  115. Okay, thanks!
    I'll try it, hence I tell how things go :D

    ReplyDelete
  116. I suposse that my T1 must be the 2sc3320 and my T2 the 2n2222?

    ReplyDelete
  117. OK, that will do, just calculate the parameters as per the given formula....

    ReplyDelete
  118. What is the voltage rating of the LEDs?? if it's 12V then you can put them in parallel and connect the assembly with the above mentioned circuit. The supply will need to be around 12V

    ReplyDelete
  119. Thankyou very much for your quick respond,According to manufacturer data,the LED has 10 wATT AND 700mlamp.So that means,the max. Voltage is around 14v.but even with this one the brightness is not good.so i put the 5 nos in parallel and connect them with the circuit and with SMPS gave 26v,1.5amp.then the brighteness was good.Is it the right way?one more question:-is it necessary to put a limiting R for each LED or not?

    ReplyDelete
  120. No it's not the right way...for 5 LEDs in parallel the current input should be equal to 0.7 x 5 = 3.5 amp..or 4 amps

    Therefore the input supply source should be rated at 14V 4 amps.

    If you use the above explained current limiter circuit then the LEDs will not required individual resistors.

    ReplyDelete
  121. yes, Even if you have calculated it correctly it will still dissipate some heat but might not burn out.

    to minimize heat you can either double the wattage value, or add a small aluminum plate with it as heatsink.

    ReplyDelete
  122. ....because the calculated wattage is the approximate breakdown value, below this value the resistor might start burning, so this value will just safeguard the resistor but not stop from heating

    ReplyDelete
  123. Thank you very much it was helpful. I question arises, you could use the same scheme replacing the transistor by a MOSFET?

    ReplyDelete
  124. you can use a small metal clamp and fix the heatsink with the resistor using screw nuts, make sure the resistor is a wire wound type

    ReplyDelete
  125. yes that's possible, actually I have discussed this elaborately in the comments above with one of the members....please go through it for the details.

    ReplyDelete
  126. What about cooling of both the power transistor and the LED

    ReplyDelete
  127. Thankyou very much sir!your website complitelly changed my hobby.So i want to learn more and more.That is why i dont want to buy anything.Instead i want to
    make it.So i will wait till you publish it.

    ReplyDelete
  128. Sir!
    still i am waiting of the remote module for this circuit.I hope you didnt forgot it.Thanks.

    ReplyDelete
  129. thank you for the reminder, I'll try to publish it within a couple of days.

    ReplyDelete
  130. I have published the article here

    https://homemade-circuits.com/2016/11/remote-controlled-solar-lamp-intensity.html

    ReplyDelete
  131. Thankyou Sir!I got it.
    I will report the result as soon as I finished it.

    ReplyDelete
  132. Hello!

    T1;T2 value? Thank you. Great circuit!

    ReplyDelete
  133. hey i want to make a circuit of 12V 8A AC/DC to run my project. Also I want it to be as compact as is can one like MVAB120 which is just 2" wide and 4" in lenght. Is it possible to make one my own. ur help is required.

    ReplyDelete
  134. sorry I do not have a 12V 8A SMPS circuit at the moment....

    ReplyDelete
  135. Dear sir,

    I had 50W LED but getting much illumination than required so i want to know how to reduce the 50W illumination Please suggest me.

    ReplyDelete
  136. please suggest me to reduce the brightness of the LED

    ReplyDelete
  137. Santhosh, did you calculate the limiting resistor value correctly as suggested in the above article??

    If it's calculated correctly then the LED will safely consumed the required amount of current.

    If you provide the voltage and the current specs of your LED I might try to calculate it for you...

    ReplyDelete
  138. But where is the circuit diagram

    ReplyDelete
  139. for the input power you can use either a 35V transformer based power supply or an smps as described below

    https://homemade-circuits.com/2014/09/32-v-3-amp-smps-led-driver-circuit.html

    ReplyDelete
  140. Hi, Swagatam,
    I happened to come across your circuit and write up as i was trying to find some information for a diy project I am trying. I have a 50 w led chip light. Can I use a 12v 1a ad-dc adaptor to power it? what is the best way to power up the chip light for continous use? Any assistance would be much appreciated.

    ReplyDelete
  141. Hi Latif, 12V 1 amp cannot be used for driving a 50 watt LED optimally, because 12 x 1 = 12 watts, whereas your LED requires 50 watts.
    so please identify the V and I specs of your LED and supply the specified amount power to it, without forgetting a current controller stage in the middle.

    ReplyDelete
  142. Hi swagatam, is it possible to drive a 100 watt led directly from 220 volt using capacitor based power? As for volt is 32 volt can we put more nos of such 100 watt led to match ouput of capacitor volt. Can capacitor based power supply handle 3 amp of current?

    ReplyDelete
  143. Hi Webmaster, yes a capacitive power supply can be built for driving a 100 watt LED using the technique that's explained in the following article:

    https://homemade-circuits.com/2016/07/scr-shunt-for-protecting-capacitive-led.html

    ReplyDelete
  144. Thanks. Can we use mpp type of capacitor like used in induction motor? These are easily available and cheap too.

    ReplyDelete
  145. you can use any type, it just needs to be a non-polar and rated at 400V

    ReplyDelete
  146. Sir!
    instead of a single 100 watt Led,i want to use 100 noes of 1 watt Leds by configuring them in series and parallel appropriately.Is it necessary to calculate and connect a resistor for each of
    series line?I think by doing that,i can get a light even iff one of the series line going to burn out.
    Isn`t it? Or you mean in this case ,there is no need of this circuit at all.I am confused.help me pls.

    ReplyDelete
  147. Shigida, a current controller will be required for all high LED circuits, for your application you can try the following concept and apply it as per the available voltage specification

    https://www.homemade-circuits.com/make-this-1000-watt-led-flood-light/

    ReplyDelete
  148. Sir!
    Thankyou so much for your quick respond.
    But I want to vary the brightness of 100 watt led ( 100 noes of 1 watt leds)by useing a variable resistance for R2.How can I solve this problem with the new concept that you suggest me?Or for the sake of varying brightness,I have to stick with this circuit and combine it with the circuit of your suggestion?

    ReplyDelete
  149. Shigida, you can use the the first design from the following article:

    https://www.homemade-circuits.com/how-to-make-current-controlled-12-volt/

    Make sure to replace LM317 with LM338, fix Rc value as per the calculations.

    And then you can use the voltage control pot for varying the brightness.

    use a 22k pot for R2, and use a 24V as the input.

    connect the LEDs as explained in the previously linked artilce.

    ReplyDelete
  150. Ritesh Kumar MohantyMarch 30, 2018 at 5:26 PM

    Thanks Sir, Sir how I can get 35 volt through a 12 v transformer Power Supply.? And how much led I can use for 100watt led? Is it 102 leds ?

    ReplyDelete
  151. Hi Ritesh, you wanted to use 1 watt LEDs, right? Therefore the shown circuit is designed using many series parallel 1 watt LEDs for creating a 100 watt LED module.

    yes 102 LEDs will be required and will need to be connected as shown in the diagram.

    Make sure to use a good heatsinking with the whole module.

    ReplyDelete
  152. Ritesh Kumar MohantyMarch 30, 2018 at 7:30 PM

    Thanks Sir, Sir where I should use the heat sink,?And what is the specification of good heat sink,,,?

    ReplyDelete
  153. Ritesh Kumar MohantyMarch 30, 2018 at 7:47 PM

    Thanks Sir,Sir how I can get 35 volt from 12volt transformer ?

    ReplyDelete
  154. as per the shown diagram you will need only 12V, 10 amps for the operating the 102 LEDs

    ReplyDelete
  155. first find out how much total area the 102 LEDs would consume. next buy an aluminum sheet, 2mm thick with area as per the LED distribution measurement.

    after that mark straight lines on the aluminum and determine the exact spots where the LeDs needs to be stuck on these line

    as per the diagram layout start sticking the flat base of the 1 watt LeDs tightly with fevibond, use only fevibond no other adhesive.

    make sure that the polarity are perfectly correct.

    keep for drying, once hard and dry...start wiring the LED ends as per the diagram...and finally finish the remaining connections also as per the schematic.

    test the module with the supply, if all the LEDs light up successfully you can assume that the LED were correctly fixed with no polarity errors, if not then check those specific series connections for the fault.

    once everything is fixed, reinforce the LEDs on the aluminum with transparent epoxy glue such as Araldite....keep for drying until hard.

    ReplyDelete
  156. Ritesh Kumar MohantyMarch 30, 2018 at 8:23 PM

    Sir where I can use the heat sink in this circuit? What is the specification of heat sink?

    ReplyDelete
  157. use heatsinks for the LEDs and the transistors

    ReplyDelete
  158. Ritesh Kumar MohantyMarch 30, 2018 at 9:37 PM

    Thanks Sir,But sir my query is where I can connect heat sink in this given circuit? and what is the specification of heat sink? Plz sir help me.

    ReplyDelete
  159. Ritesh, I have already explained elaborately in the previews comment, please check the previous replies...

    ReplyDelete
  160. Ritesh Kumar MohantyMarch 30, 2018 at 10:12 PM

    Thanks Sir,Sir Is the aluminum plate is the heat sink used in this. Circuit?

    ReplyDelete
  161. yes heatsinks are always made with aluminum, make sure that the aluminum plate is much bigger than the area of the LED measured...you can bend the extra length of the aluminum backwards at 90 degrees to make the design compact

    ReplyDelete

Post a Comment