Skip to main content

2 Simple Earth Leakage Circuit Breaker (ELCB) Explained

The discussed Earth leakage circuit breaker diagrams will silently monitor the electrical condition of your appliances and the Earth connection of your house. Here we will learn 2 designs, first using transistors only and the second using IC LM324.

Introduction

If anything goes wrong with them it will instantly switch off the mains and stop any further associated loss. A simple ELCB circuit is discussed here.

A simple circuit of an Earth leakage circuit breaker also called ground fault circuit interrupter is discussed in this article.

The circuit once built and installed will silently monitor the “health” of the earth connection of your house and the connected appliance.

The circuit will immediately switch off the mains on detecting a missing earth connection or a current leakage through the appliance body.

Why You Need an ELCB


A leaking current through earth terminal is probably more dangerous than a short circuit in a domestic wiring.

A short circuit hazard is visible and mostly tackled through a fuse or a circuit breaker unit.

But earth current leakages may remain hidden for years, eating up your precious electricity and also weakening or deteriorating the wiring conditions and also the appliances.

Moreover if the earth connection is not properly grounded due to improper conduction or breakage, the leakage may turn into a lethal shock over the body of the appliance.

Cons of Commercial ELCB Units


Commercially available earth leakage circuit breaker units are very costly and bulky, involving complicated installation procedure.

I have designed a simple circuit which is low in cost and yet handles the situation handsomely. The device will detect any current exceeding above 5mA through the earth passage and switch off the mains.

The connected appliance will then need a diagnose or a total elimination. A leaking appliance not only wastes your electricity but also can be dangerous fatally.

Circuit diagram using Transistors

Earth Leakage Circuit Breaker (ELCB) Circuit

Simulation and Working


The proposed ground fault circuit interrupter or ELCB utilizes a simple principle of detecting the AC signal rather the applied or the leaking voltage.

Here, the leaking AC may be too small to be detected as a potential difference using simple voltage detection configuration, therefore the leakage is effectively sensed as a frequency, using a simple audio amplifier stage.

As shown in the diagram, a simple bootstrapped amplifier network forms the main sensing stage of the unit. Transistors T1 and T2 along with the associated passive components are wired up into a small two stage amplifier.

The introduction of R3 becomes very crucial as it provides a positive feed back to the input making the circuit more stable and respond to minutest input signals.

The inductor L1 basically has two windings, the primary which is connected to the earth point of the socket has less number of turns, the secondary winding has six times more number of turns and is integrated to the input of the circuit via C1.

The role of L1 is to amplify any AC induced into its primary winding which can only happen in case of a leakage through the body of an appliance connected to the socket.

The above amplified leakage voltage is further amplified to a level enough to activate RL1, instantly disabling the input to the appliance and indicating the earth leakage fault.

Capacitor C5 along with D3 and C4 forms a standard transformerless power supply to power the circuit.

D3 performs a dual function of rectification and surge suppression. Interestingly the main earth connection itself becomes the negative of the circuit instead of the neutral line.

Also since RL2 is directly connected to the supply across the positive of the circuit and the earthing, simply means that if the earthing becomes weak or disconnected, the relay will deactivate, cutting off the AC mains to the appliance, so it effectively indicates the health of the earthing and safeguards the house from faulty or missing earth connections.

ELCB Circuit Parts List.


R1 = 22K,

R2 = 4K7,

R3 = 100K,

R4 = 220E,

R5 = 1K,

R6 = 1M,

C1 = 0.22/50V,

C2 = 47UF/25V,

C4 = 10uF/250V,

C5 = 2UF/400V PPC,

T1, T2 = BC 547B,

T3 = BC 557B,

Relays = 12V, 400 Ohm, SPDT,

All Diodes are = 1N4007,

L1 = Coil wound over a bobbin used normally with E-cores (smallest size,) begin winding 50 turns of 25 SWG wire first, tie it up and solder it to produce the primary terminals at one side of the bobbin. Now using 32 SWG copper wire, wind 300 turns over the primary winding, as before tie the ends to the other side of the bobbin by soldering. Insert and fix the coil within the E-cores. Secure it tightly using PVC tape

How to Make a Homemade Earth Leakage Breaker (ELCB) Unit Using IC 324


An earth leakage circuit breaker is a safety electrical device used for monitoring current leakages through the “earthing” terminal and switching OFF the mains when this leakage exceeds a certain dangerous level.

Introduction


Normally electromechanical concepts are employed for making these devices, however here we will see how an ELCB can be made by using ordinary electronic components; we will also see why an electronic counterpart is more efficient than the commercial electromechanical units.

There are three versions through an electronic ELCB can be made, the first uses a relay for the switching actions, the second idea incorporate a Triac and the third concept employs a SSR or a solid state relay for the required implementations.

For all the above concepts, the triggering feature remains the same, through an input inductor stage.

mains earthing circuit breaker using SCR switch

ELCB Circuit Using Relay


Looking at the figure we can see that the entire circuit is concentrated around a single Opamp from the IC 324. The op amp is configured as a high gain inverting amplifier.

The op amp is configured as a high gain AC amplifier and its sensitivity can be adjusted by varying the value of R2, increasing its value increase the sensitivity of the circuit.

Any minute AC signal that may be present at the inverting input #2 of the IC is picked via the coupling capacitor C1 and instantly amplified by the IC.

A small inductor transformer is wired across the above input of the IC. The primary of the inductor is connected to the wire which finally terminates to the earthing terminal or the pin of the various 3-pin sockets in the premise.

The transformer can be an ordinary output transformer used in small radio receiver’s output amplifier stage.

In case of a leakage, the leaking current passes through the primary winding of the inductor and gets stepped up at the secondary winding.

The stepped up induced AC is immediately sensed by the IC input and further amplified to the desired levels, so that the SCR switches in response to the triggering.

The SCR, due to its inherent property instantly latches and pulls the relay into conduction.

The relay conducts and switches OFF the mains power to the three pin sockets, switching of the appliances and thus eliminating earth leakage conditions.



simple ELCB circuit with triac solid state version

ELCB Circuit Using a Triac


The above circuit can also be implemented using a Triac, everything remains the same, except the relay stage, which now gets replaced by a Triac.

During normal conditions the IC output remains switched OFF and the triac is allowed to conduct and operate the load.

However the moment a leakage is sensed, the IC output goes high, which triggers the SCR and latches its anode to ground. This inhibits the gate current to the triac which instantly stops conducting, switching OFF the load and rectifying the unfavorable conditions.

compact reliable ELCB circuit using SSR

ELCB Circuit Using an SSR or SolidState Relay


Mians operated SSR devices are nowadays being effectively employed for switching mains operated loads more efficiently than relays and since these are electrically isolated and solid state in nature, becomes more desirable than the conventional switching devices like triacs and relays.

Here, as long as the conditions are normal, the SSR is able to derive the required input triggering voltage from the circuit, however the moment a leakage is anticipated, the circuit triggers the SCR which in turn chokes the SSR input trigger to ground. The SSR instantly stops conducting, implementing the intended actions by tripping the load and prevents any possible hazard.

Parts List


R1 = 100K,

R2 = 1M,

R3, R4, R5 = 1K,

C1 = 0.01uF

C2 = 100uF/25V

L1 = ordinary small output transformer as used in transistor radios.

SCR = BT169

Triac = BT 136 or higher current type

Op amp = ¼ IC324

SSR = As per user specs.

Relay = 12V, SPDT

WARNING: ALL THE CONCEPTS ARE DESIGNED AS PER THE AUTHOR'S SIMULATED ASSUMPTION. PLEASE PROCEED WITH CAUTION WHILE TESTING IT PRACTICALLY

Need Help? Please leave a comment, I'll get back soon with a reply!




Comments

  1. It will switch off the load whose body may be leaking current on the earth line.

    this circuit will not protect from under/over voltages.

    ReplyDelete
  2. HELLO, Pls is the circuit working efficiently because i wll like to use it as my school project..thanks in advance..

    ReplyDelete
  3. It has not yet been tested practically, however as per my mind simulation there's no way this cannot work if built correctly....the trafo is criucial here

    ReplyDelete
  4. PLS,, is the C1 polar capacitor or non polarized and the is no C6 in the circuit as you have named it

    ReplyDelete
  5. I have corrected the parts list, please check it out now...

    ReplyDelete
  6. hello Neha, it will do if it is able to amplify small mV AC to at least 2V AC...for example a small audio-output type of transformer will work here

    ReplyDelete
  7. Hello..swagatamsir.

    I want to use this circut for ur another project high volt ignition coil...i want to blow siren instend of switch off done with above circuit..can I use this circuit for my fencing ..and if it is possible than which type of change I have to make in above circuit..

    ReplyDelete
  8. Hello Sanjay, yes it's a viable idea you can try but make sure you try the above circuit separately first on your work bench...once it's confirmed then you go for the final implementation.

    ReplyDelete
  9. Please help me with abstract of this simple earth leakage circuit breaker i need it please.

    ReplyDelete
  10. sorry sehu, writing abstract can be quite time consuming and won't be possible for me at this moment.

    ReplyDelete

Post a Comment